ADJUSTMENT
6 - 15
<Adjustment procedure summarization for A to E>
[0] [5] [Power ON] [1] ([3](05-4062, 05-4019) for duplex) [FAX]
A: 05-4001 (2nd drawer, A3/LD)
200±0.5 mm
(e-STUDIO556/656: 0.3 mm/step,
e-STUDIO756/856: 0.1 mm/step)
B: 05-4006 (2nd drawer, A3/LD)
52±0.5 mm (0.05 mm/step)
C: 05-4527 (2nd drawer, A3/LD)
200±0.5 mm (0.5 mm/step)
D: 05-4402 (All, A3/LD (recommended)
05-4058 (1st drawer),
05-4060 (3rd drawer * JPC model only),
05-4560 (4th drawer * JPC model only),
05-4063(LCF),
05-4061 (Bypass feed),
05-4062 (Duplexing)
52±0.5 mm (0.4 mm/step)
E: 05-4019-0 (2nd drawer, A3/LD),
05-4019-1 (1st drawer/Tandem LCF, A4/
LT)
05-4019-2 (A4-R/LT-R)
52±0.5 mm (0.05 mm/step)