ERROR CODE AND TROUBLESHOOTING
8 - 146
[F106_6]/[F106_7]/[F106_8]/[F106_10] /[F106_UNDEF] ADI-HDD error: Error caused by reason
other than F106_0 to 5 errors
[F109_0] Key consistency error (Consistency check operation error)
Classification Error item
Other service call ADI-HDD error: Error caused by reason other than F106_0 to 5 errors
Check item Measures
Setting Perform [3]+[C]+[POWER] → [3.Format HDD], and then install the system
software by performing [4]+[9]+[POWER] → [4.System Software (HD
data)].
The following items will be deleted by performing [3]+[C]+[POWER]
→ [3.Format HDD].
• Message Log
• Job Log
• Spool Data (Print, Email reception)
• Template
Classification Error item
Other service call Key consistency error - Key consistency check on each key data fails.
Check item Measures
Setting
Reboot the equipment.
If it cannot be recovered, reinstall the software in the following procedure.
• Install the OS data.
P.11-12 "11.2.3 Master data / System ROM / Laser ROM / PFC
ROM / Engine ROM / Scanner ROM / RADF ROM"
• Reinstall the master data and application program.
P.9-15 "9.2.3 Precautions and procedures when replacing the HDD"
[E] Replace / Format HDD Step (3) and later in [E] Replace /
Format HDD
SRAM board
If the error is not cleared after the software reinstallation, replace the SRAM
board. P.9-27 "9.2.7 Precautions and Procedures when replacing
SRAM board"
SYS board
If the error is not cleared after this (see above), replace the SYS board.
P.9-20 "9.2.4 Precautions and Procedures when replacing the SYS
board (for e-STUDIO556/656/756/856)"
Replace parts Remarks
SRAM board
SYS board