e-STUDIO556/656/756/856
71
05/08 Mode Element
Sub
element
Item Subitem Code
Sub-
code
Details
Default
value
Acceptable
value
RAM Contents
Proce
dure
Servic
e UI
08
Setting
Mode
Counter Pixel counter 6505
Displayed reference
setting
0 0~1 SYS
Selects the reference when displaying the pixel counter
on the LCD screen. 0: Service technician reference 1:
Toner cartridge reference
1
08
Setting
Mode
Counter Pixel counter 6506
Toner empty
determination counter
setting
0 0~1 SYS
Selects the counter to determine toner empty.0: Output
pages 1: Pixel counter
1
08
Setting
Mode
Counter Pixel counter 6507
Threshold setting for
toner empty
determination(Output
pages)
500 0~999 SYS
Sets the number of output pages to determine toner
empty. This setting is valid when "0" is set at 08-6506.
1
08
Setting
Mode
Counter Pixel counter 6508
Threshold setting for
toner empty
determination(Pixel
count)
21500 0~60000 SYS
Sets the pixel count to determine the toner empty
status. This setting is valid when "1" is set at 08-6506.
1
08
Setting
Mode
Counter Pixel counter 6509
Pixel counter clear
flag/Service
technician reference
0 0~1 SYS Becomes "1" when 08-6502 is performed. 2
08
Setting
Mode
Counter Pixel counter 6510
Service technician
reference cleared
date
- 8 digits SYS Displays the date on which 08-6502 was performed. 2
08
Setting
Mode
Counter Pixel counter 6514
Toner cartridge
reference cleared
date
- 8 digits SYS Displays the date on which 08-6503 was performed. 2
08
Setting
Mode
Counter Pixel counter 6522
Toner cartridge
reference count
started date
- 8 digits SYS Displays the date on which 08-6503 was performed. 2
08
Setting
Mode
Counter Pixel counter
Number of output
pages(Service
technician reference)
6558 PPC 0 8 digits SYS
Counts the number of output pages converted to the
standard paper size in the copy function and service
technician reference.[Unit. page]
2
08
Setting
Mode
Counter Pixel counter
Number of output
pages(Service
technician reference)
6560 PRT 0 8 digits SYS
Counts the number of output pages converted to the
standard paper size in the printer function and service
technician reference.[Unit. page]
2
08
Setting
Mode
Counter Pixel counter
Number of output
pages(Service
technician reference)
6561 FAX 0 8 digits SYS
Counts the number of output pages converted to the
standard paper size in the FAX function and service
technician reference.[Unit. page]