EasyManua.ls Logo

Toshiba E-STUDIO600 - Page 458

Toshiba E-STUDIO600
592 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
e-STUDIO520/600/720/850 TROUBLESHOOTING March 2005 © TOSHIBA TEC
5 - 130
5) Blurred image
Fig.5-5
Defective area Step Check items Prescription
Paper 1 Is the paper in the drawer or LCF
damp?
Change paper. Avoid storing paper in
damp place.
Bedewed scanner 2 Is the scanner bedewed? Clean the scanner.
Drum 3 Is the drum surface wet or dirty? Wipe the drum with a piece of dry
cloth.
* Do not use alcohol or other
organic solvents.
Feeding direction

Table of Contents

Related product manuals