e-STUDIO520/600/720/850 FIRMWARE UPDATING March 2005 © TOSHIBA TEC
6 - 14
(8) “Update Completed.” is displayed at the bottom of the LCD screen after the updating is com-
pleted properly.
Fig.6-13
“Update Failed.” is displayed at the bottom of the LCD screen when the updating is not com-
pleted properly. “Failed” appears next to the failed item on the status display.
• Is the download jig connected properly?
• Is the updating data written to the download jig properly?
• Do the download jig and the equipment operate properly?
Fig.6-14
(9) Turn OFF the power, remove the download jig and install the cover plate.
(10) Perform the initialization of the updating data.
• Turn ON the power while [0] button and [8] button are pressed simultaneously.
• Key in “947”, and then press the [START] button.
• Press the [INITIALIZE] button.
05/05