March 2005 © TOSHIBA TEC e-STUDIO520/600/720/850 ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 47
2
299 Image
quality
control
Image quality open-loop
control enforcement
ALL - M When a service call has
occurred or a warning
message (IQC/SPC) has
appeared, "Image quality
control enforcement (05-
290)" should be per-
formed after the equip-
ment is repaired or the
cause of the error is
evaluated. In case the
service call occurred or
the warning message
(IQC/SPC) appeared
again after the perfor-
mance of the code 05-
290, a test chart can be
printed out by tempo-
rarily using this code (05-
299) if an image check is
urgently needed.
6
305 Scanner Image location adjustment
of secondary scanning
direction
(scanner section)
ALL 140
<92-164>
SYS When the value
increases by “1”, the
image shifts by approx.
0.143 mm toward the
trailing edge of the
paper.
1
306 Scanner Image location adjustment
of primary scanning direc-
tion
(scanner section)
ALL 135
<0-255>
SYS When the value
increases by “1”, the
image shifts by approx.
0.169 mm toward the
front side of the paper.
1
308 Scanner Distortion mode ALL - - Moves carriages to the
adjusting position.
(Ch.3.2.4)
6
310 Scanner Shading posi-
tion adjust-
ment
Original
glass
ALL 0
<0-11>
SYS 0.1433 mm/step 1
311 RADF ALL 0
<0-5>
SYS 0.1433 mm/step 1
340 Scanner Reproduction ratio adjust-
ment of secondary scan-
ning direction
(scanner section)
ALL 128
<0-255>
SYS When the value
increases by “1”, the
reproduction ratio in the
secondary scanning
direction (vertical to
paper feeding direction)
increases by approx.
0.223%.
1
352 RADF EEPROM initialization ALL - SYS EEPROM is initialized. 6
354 RADF Adjustment of
RADF paper
alignment
for single -
sided orig-
inal
ALL 10
<0-20>
SYS When the value
increases by “1”, the
aligning amount
increases by approx.
0.5 mm.
1
355 for double
sided orig-
inal
ALL 10
<0-20>
SYS 1
Adjustment mode (05)