e-STUDIO520/600/720/850 ERROR CODE AND SELF-DIAGNOSTIC MODE March 2005 © TOSHIBA TEC
2 - 48
356 RADF Automatic adjustment of
RADF sensor
ALL - SYS Performs the adjustment
and initialization when
the RADF board or
RADF sensor is
replaced.
6
357 RADF Fine adjustment of RADF
transport speed
ALL 50
<0-100>
SYS When the value
increases by “1”, the
reproduction ratio of the
secondary scanning
direction when using the
RADF increases by
approx. 0.1%.
1
358 RADF RADF sideways deviation
adjustment
ALL 120
<0-255>
SYS When the value
increases by “1”, the
image of original fed
from the RADF shifts
toward the rear side of
paper by approx.
0.0846 mm.
1
359 Scanner Carriage position adjust-
ment during scanning from
RADF
ALL 128
<0-255>
SYS When the value
increases by “1”, the car-
riage position when
using the RADF shifts by
approx. 0.1 mm toward
the original feeding side.
1
365 RADF RADF lead-
ing edge posi-
tion
adjustment
for single -
sided orig-
inal
ALL 50
<0-100>
SYS When the value
increases by “1”, the
copied image of original
fed from the RADF shifts
toward the trailing edge
of paper by approx.
0.1 mm.
1
366 for double
sided orig-
inal
ALL 50
<0-100>
SYS 1
367 RADF RADF original guide width
adjustment
(Minimum)
ALL - - Stores the current width
of RADF original guide
by keying in this code
with the guide set at the
minimum width. Perform
this adjustment when the
RADF board or volume is
replaced, or when the
code (05-352) is per-
formed.
6
368 RADF RADF original guide width
adjustment
(Maximum)
ALL - - Stores the current width
of RADF original guide
by keying in this code
with the guide set at the
maximum width. Per-
form this adjustment
when the RADF board or
volume is replaced, or
when the code (05-352)
is performed.
6
Adjustment mode (05)
Code
Classi-
fication
Items
Func-
tion
Default
<Accept-
able
value>
RAM Contents
Proce-