e-STUDIO5506AC/6506AC/7506AC (Ver01) © 2016, 2017 TOSHIBA TEC CORPORATION All rights reserved
1 - 20
1. General Adjustments – Copying, Printing and e-Filing (Output from Box)
<Note> Do not disable the Auto shut off mode timer setting ("0" is set for 08-9112) while the
Auto power save timer setting is set to invalid ("0" is set for 08-9111). If both settings are
set to invalid, this equipment does not enter the energy saving mode so it is always in the
ready status. Due to this, image quality control according to the period of time the MFP
is left unused is not performed regardless of the setting value of 08-2507.
• After setting the value for code 08-2507, forcibly perform image quality control, as follows:
Select [05 ADJUSTMENT MODE], select code [2742], and then press the [START] button.
(1)-4. To optimize the image quality stability according to the number of output pages in a day or
the type of originals:
By changing the setting value for [08] codes, the image quality control can be started at the desired timing
after the specified number of pages have been output. Referring to the guide below, set the value
appropriately in accordance with the total number of pages output in a day, the number of jobs frequently
performed, or the requested image quality in the user’s office.
After changing the setting value, perform the image quality control following the procedure below.
Select [05 ADJUSTMENT MODE]. Select code [2742]. Press the [START] button.
After performing the adjustment, print the image and check its quality.
Printing
interrupted
08-9199 50
*6. To start the Short Mode at every 30 pages, set the value to “30” for both 08-2497 and 08-9199. However,
setting a too-short interval will use up too much toner, even though the consumption in the Short Mode is
approximately a quarter of that in the Full Mode.