1. General Adjustments – Copying, Printing and e-Filing (Output from Box)
<Note> Do not disable the Auto shut off mode timer setting ("0" is set for 08-9112) while the
Auto power save timer setting is set to invalid ("0" is set for 08-9111). If both settings are
set to invalid, this equipment does not enter the energy saving mode so it is always in the
ready status. Due to this, image quality control according to the period of time the MFP
is left unused is not performed regardless of the setting value of 08-2507.
After setting the value for code 08-2507, forcibly perform image quality control, as follows:
Select [05 ADJUSTMENT MODE], select code [2742], and then press the [START] button.
(1)-4. To optimize the image quality stability according to the number of output pages in a day or
the type of originals:
By changing the setting value for [08] codes, the image quality control can be started at the desired timing
after the specified number of pages have been output. Referring to the guide below, set the value
appropriately in accordance with the total number of pages output in a day, the number of jobs frequently
performed, or the requested image quality in the users office.
After changing the setting value, perform the image quality control following the procedure below.
Select [05 ADJUSTMENT MODE]. Select code [2742]. Press the [START] button.
After performing the adjustment, print the image and check its quality.
(A). For standard office use (mainly business documents) (Default)
Code to set
number of
pages
Setting
value
Starting conditions
Full IQC
08-2509
2000
The control starts after every 2000 pages.
Short IQC 08-2497 250
The control starts after 250 pages have been output, or when
a job is interrupted after every 500 pages.
Printing
interrupted
08-9199 500
(B). To stabilize the density in continuous copying/printing(when interrupting jobs and
starting the Short Mode at every 50 pages)
Code to set
number of
pages
Setting
value *6
Starting conditions
Full IQC 08-2509 2000 The control starts after every 2000 pages.
Short IQC
08-2497 50
The control starts when a job is interrupted after every 50
pages.
Printing
interrupted
08-9199 50
*6. To start the Short Mode at every 30 pages, set the value to “30” for both 08-2497 and 08-9199. However,
setting a too-short interval will use up too much toner, even though the consumption in the Short Mode is
approximately a quarter of that in the Full Mode.