ERROR CODE and TROUBLESHOOTING
6 - 6
E712 RADF jam Jam not reaching the original registration sensor:
The original fed from the original feeding tray does
not reach the original registration sensor.
P. 6 - 5 0
E714 Feed signal reception jam: The feed signal is
received even no original exists on the original
feeding tray.
P. 6 - 5 0
E721 Jam not reaching the original reading start sensor:
The original does not reach the reading start sensor
after it has passed the registration sensor (when
scanning obverse side) or the reverse sensor
(when scanning reverse side).
P. 6 - 5 0
E722 Jam not reaching the original exit sensor (during
scanning): The original which passed the read
sensor does not reach the original exit/reverse
sensor when it is transported from the scanning
section to exit section.
P. 6 - 5 1
E724 Stop jam at the original registration sensor: The
trailing edge of the original does not pass the
original registration sensor after its leading edge
has reached this sensor.
P. 6 - 5 1
E725 Stop jam at the reading start sensor: The trailing
edge of the original does not pass the read sensor
after its leading edge has reached this sensor.
P. 6 - 5 0
E726 Transport/exit signal reception jam during ADF
standby status
P. 6 - 5 1
E727 Jam not reaching the original reading end sensor P. 6-51
E729 Stop jam at the original reading end sensor P. 6-51
E731 Stop jam at the original exit/reverse sensor: The
trailing edge of the original does not pass the
original exit/reverse sensor after its leading edge
has reached this sensor.
P. 6 - 5 2
E744 Stop jam at the exit/reverse sensor P. 6-52
E745 Jam not reaching the exit reverse sensor P. 6-52
E746 Exit/reverse sensor paper remaining jam P. 6-52
E762 Registration sensor paper remaining jam P. 6-52
E770 Original width detection sensor-1 paper remaining
jam
P. 6 - 5 2
E771 Original width detection sensor-2 paper remaining
jam
P. 6 - 5 2
E772 Original width detection sensor-3 paper remaining
jam
P. 6 - 5 2
E773 Intermediate transport sensor paper remaining jam P. 6-52
E774 Reading start sensor paper remaining jam P. 6-50
E775 Reading end sensor paper remaining jam P. 6-52
E777 Exit sensor paper remaining jam P. 6-52
E860 Original jam access cover open: The Original jam
access cover has opened during RADF operation.
P. 6 - 5 3
E870 RADF open jam: RADF has opened during RADF
operation.
P. 6 - 5 3
E871 Cover open jam in the read ready status: Jam
caused by opening of the Original jam access cover
or front cover while the RADF is waiting for the
scanning start signal from the equipment.
P. 6 - 5 3
E890 ADF time out jam P. 6-53
Error code Classification Contents Troubleshooting