6
© 2012 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO556/656/756/856(Ver03)
ADJUSTMENT
6 - 93
(8) Measure the distance (L) between the stitching position and the folding position. Then, perform
"positive width adjustment" or "negative width adjustment" to suit the relationship between the
stitching position and the folding position.
If the stitching position is below the folding position, perform "positive width adjustment."
If the stitching position is above the folding position, perform "negative width adjustment."
Fig. 6-115
Mark
Positive Width Adjustment
Folding position
Stitching position
Unit: mm
Example: If L is 1 mm, provide “+1 mm”.
L
Mark
Negative Width Adjustment
Folding position
Stitching position
Unit: mm
Example: If L is 0.5 mm, provide “-0.5 mm”.
L