ERROR CODE AND TROUBLESHOOTING
8 - 146
[F106_6]/[F106_7]/[F106_8]/[F106_10] /[F106_UNDEF] ADI-HDD error: Error caused by reason
other than F106_0 to 5 errors
[F109_0] Key consistency error (Consistency check operation error)
Classification Error item
Other service call ADI-HDD error: Error caused by reason other than F106_0 to 5 errors
Check item Measures
Setting Perform [3]+[C]+[POWER] [3.Format HDD], and then install the system
software by performing [4]+[9]+[POWER] [4.System Software (HD
data)].
Notes:
The following items will be deleted by performing [3]+[C]+[POWER]
[3.Format HDD].
Message Log
Job Log
Spool Data (Print, Email reception)
Template
Classification Error item
Other service call Key consistency error - Key consistency check on each key data fails.
Check item Measures
Setting
Reboot the equipment.
If it cannot be recovered, reinstall the software in the following procedure.
Install the OS data.
P.11-12 "11.2.3 Master data / System ROM / Laser ROM / PFC
ROM / Engine ROM / Scanner ROM / RADF ROM"
Reinstall the master data and application program.
P.9-15 "9.2.3 Precautions and procedures when replacing the HDD"
[E] Replace / Format HDD Step (3) and later in [E] Replace /
Format HDD
SRAM board
If the error is not cleared after the software reinstallation, replace the SRAM
board. P.9-27 "9.2.7 Precautions and Procedures when replacing
SRAM board"
SYS board
If the error is not cleared after this (see above), replace the SYS board.
P.9-20 "9.2.4 Precautions and Procedures when replacing the SYS
board (for e-STUDIO556/656/756/856)"
Replace parts Remarks
SRAM board
SYS board