e-STUDIO556/656/756/856
6
05/08 Mode Element
Item Subitem Code
Details
RAM Contents
Mode
setting at the end of
cleaning web
0 0~1 M 0: Stop operation 1: Continue operation 1
Mode
correction switching
0: Approx. 0.75% lower than current status
1: Approx. 0.50% lower than current status
2: Approx. 0.25% lower than current status
3: Unchanged (Default)
4: Approx. 0.15% higher than current status
5: Approx. 0.25% higher than current status
6: Approx. 0.50% higher than current status
7: Approx. 0.75% higher than current status
Mode
correction/ New toner
supply motor control
The supply amount of new toner to the developer unit
(the
drive counts of the new toner supply motor) is
corrected.
Smaller<-Toner supply amount->Larger
5->4->3->1->0->2->6->7->8
Mode
correction/ Hopper
motor control
The supply amount of recycle toner to the developer
unit (the drive counts of the hopper motor) is corrected.
Smaller<-Toner supply amount->Larger
3->1->0->7->6->5->4->8->2
Mode
control switching
This setting is whether the recycle toner is supplied or
not when the toner cartridge is empty.
0: Supplied 1: Not supplied
Mode
operation cycle
setting
0: Disabled 1: 500 sheets interval 2: 1,000 sheets
interval 3: 1,500 sheets interval 4: 2,000 sheets interval
5: 2,500 sheets interval 6: 3,000 sheets interval
Mode
period
Mode
control
prerunning period
before image quality
closed-loop control
Mode
control
loop control(Contrast
voltage)
0 0~1 M 0: Enabled 1: Disabled 4