e-STUDIO556/656/756/856
7
05/08 Mode Element
Item Subitem Code
Details
RAM Contents
Mode
control
loop control(Laser
power)
0 0~1 M 0: Enabled 1: Disabled 4
Mode
control
loop control
0 0~1 M 0: Enabled 1: Disabled 1
Mode
control
correction control
switching against
surface potential
0 0~2 M 0: Control OFF 1: Table 1 applied 2: Table 2 applied 1
Mode
control
potential sensor
control abnormality
Mode
control
potential sensor
2851 Control setting 0 0~1 M 0: Enabled 1: Disabled 1 Yes
Mode
control
sensor abnormality
The number of times the image quality closed-loop
control error has occurred is displayed. When the
equipment has been repaired and the cause of the error
has been evaluated after the appearance of a warning
message (IQC), reset the counter to switch off.
Mode
control
Auto-start print
volume setting 1
The printing interval to perform the image quality
closed-loop control is set. Default: 2000 sheets (Setting
value x 100 sheets)
Mode
control
Auto-start print
volume setting 2
The image quality closed-loop control is performed in a
shorter printing interval than the one set in 08-2876 only
when the equipment has been left inactive for a long
time (including power-OFF).Default: 500 sheets (Setting
value x 10 sheets)
Mode
control
image quality control
auto-start
When the equipment has been left in warming-up for
more than the specified period of time, the image
quality closed-loop control is performed. This period is
set in this code.Default: 4 (Unit: hours)
Mode
control
times of image quality
closed-loop control
correction (Contrast
voltage)
The maximum number of correction which the image
quality closed-loop control (contrast voltage) can be
performed is set.