EasyManua.ls Logo

Toshiba e-STUDIO657 - Page 350

Toshiba e-STUDIO657
754 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
e-STUDIO556/656/756/856
7
05/08 Mode Element
Sub
element
Item Subitem Code
Sub-
code
Details
Default
value
Acceptable
value
RAM Contents
Proce
dure
Servic
e UI
08
Setting
Mode
Process
Image quality
control
2844 1
Image quality closed-
loop control(Laser
power)
0 0~1 M 0: Enabled 1: Disabled 4
08
Setting
Mode
Process
Image quality
control
2845
Image quality open-
loop control
0 0~1 M 0: Enabled 1: Disabled 1
08
Setting
Mode
Process
Image quality
control
2846
Transfer output
correction control
switching against
surface potential
0 0~2 M 0: Control OFF 1: Table 1 applied 2: Table 2 applied 1
08
Setting
Mode
Process
Image quality
control
Drum surface
potential sensor
2850
Counter for number of
control abnormality
0 0~16 M 1 Yes
08
Setting
Mode
Process
Image quality
control
Drum surface
potential sensor
2851 Control setting 0 0~1 M 0: Enabled 1: Disabled 1 Yes
08
Setting
Mode
Process
Image quality
control
2873
Number of times of
sensor abnormality
0 0~16 M
The number of times the image quality closed-loop
control error has occurred is displayed. When the
equipment has been repaired and the cause of the error
has been evaluated after the appearance of a warning
message (IQC), reset the counter to switch off.
1 Yes
08
Setting
Mode
Process
Image quality
control
2876
Image quality control/
Auto-start print
volume setting 1
20 0~30 M
The printing interval to perform the image quality
closed-loop control is set. Default: 2000 sheets (Setting
value x 100 sheets)
1
08
Setting
Mode
Process
Image quality
control
2877
Image quality control/
Auto-start print
volume setting 2
50 1~99 M
The image quality closed-loop control is performed in a
shorter printing interval than the one set in 08-2876 only
when the equipment has been left inactive for a long
time (including power-OFF).Default: 500 sheets (Setting
value x 10 sheets)
1
08
Setting
Mode
Process
Image quality
control
2878
Condition setting of
image quality control
auto-start
4 0~24 M
When the equipment has been left in warming-up for
more than the specified period of time, the image
quality closed-loop control is performed. This period is
set in this code.Default: 4 (Unit: hours)
1
08
Setting
Mode
Process
Image quality
control
2891 0
Maximum number of
times of image quality
closed-loop control
correction (Contrast
voltage)
5 0~10 M
The maximum number of correction which the image
quality closed-loop control (contrast voltage) can be
performed is set.
4