FC-22 TROUBLESHOOTING 4 - 42 January 2000 © TOSHIBA TEC
CC4 Guide bar swing motor rotation abnormal
At the time the guide bar swings, does pulse output occur on J13-3 to J13-6 on the sorter
controller board? In addition, does the voltage between J13-1 and J13-2 show 24V?
Check the wiring up to the guide bar swing motor (M3). If it is normal, replace the
guide bar swing motor.
Is a voltage of 24V being supplied from the copier?
Replace the sorter controller board.
Check the 24V-power supply of the copier.
CC5 Stapler-unit swing motor rotation abnormal
At the time the stapler unit swings, does the voltage between J9-1 (+) and J9-2 (–) on the sorter
controller board show 24V?
Is a voltage of 24V being supplied from the copier?
Check the 24V-power supply of the copier.
Replace the sorter controller board.
Is stapler-unit swing switch (MS9) working normally?
Replace the stapler-unit swing switch (MS9).
Does the resistance between J9-1 and J9-2 on the harness side measure approx. 25
?
Replace the stapler-unit swing motor (M5).
Replace the sorter controller board.