January 2000 © TOSHIBA TEC 1 - 33 FC-22 ADJUSTMENT
1. 2. 5 Setting mode (08)
The following items can be set or changed in this mode 08.
Allowable
Operation
Code
Name Default
input value
Contents
procedure
group
1
1
1
1
1
1
Externally installed copy counter/
controller device
200 Date and time setting 13 digits Year/month/date/day/hour/minute/second
Example: 99:08:07:5:11:30:48
201 Destination selection 2
0-3:FC15/22
0: Europe (A4/A3/Folio)
1: USA/Canada (Letter/Ledger)
0-1:FC25P
2: Japan (A4/B4) 3:Others
202 0 0-3 0: No external copy counter/controller de-
vice 1: Coin controller 2: Copy key card
3: Key copy counter
204 Auto clear time setting
3:FC22
0-10 Time-out for cleaning control panel settings
0:FC25P and returning to the default settings.
0: Disabled
1 to 10: Set number x 15 second
205 Energy saver timer setting 0
0-15: FC15/22
Timer for switching from Ready mode to
0-19:FC25P
Energy Saver selected code 618.
0: Disabled 1: 30sec. 2: 60sec.
3: 90sec. 4: 120sec. 5: 150sec.
6: 3min 7: 4min 8: 5min 9: 7min
10: 10min 11: 15min 12: 20min
13: 30min 14: 45min 15: 60min
16: 90min 17: 120min
18: 180min 19: 240min
206 Auto-power shut off setting 20 0-20 Timer for switching from Ready mode to
Auto-Power Shut OFF. US Energy Star
Compliance
0: 3min 1: 5min 2: 10min 3: 15min
4: 20min 5: 25min 6: 30min
7: 40min 8: 50min 9: 60min
10: 70min 11: 80min 12: 90min
13: 100min 14: 110min 15: 120min
16: 150min 17: 180min 18: 210min
19: 240min 20: Disabled