- 1729 -
MES_MANAGEMENT(FunctionID: 711001)
Percentage of thermal capacity for fault record / metering
Frequency of SyncRy1's VR
Frequency of SyncRy1's VI
Differential angle of SyncRy1's VR and VI
Differential frequency of SyncRy1's VR and VI
Differential angle of SyncRy2's VR and VI
Differential frequency of SyncRy2's VR and VI
I2/I1 measurement for fault record / metering
Frequency of SyncRy2's VR
Frequency of SyncRy2's VI
Vs2 measurement secondary
Vs2 measurement secondary
Va instantaneous measurement secondary for fault record
Va instantaneous measurement angle for fault record
Vb instantaneous measurement secondary for fault record
Vb instantaneous measurement angle for fault record
Vc instantaneous measurement secondary for fault record
Vc instantaneous measurement angle for fault record
Va instantaneous measurement primary for fault record
Vb instantaneous measurement primary for fault record
Vc instantaneous measurement primary for fault record
Vab instantaneous measurement secondary for fault record
Vab instantaneous measurement angle for fault record
Vbc instantaneous measurement secondary for fault record
Vbc instantaneous measurement angle for fault record
Vca instantaneous measurement secondary for fault record
Ia instantaneous measurement secondary for fault record
Vca instantaneous measurement angle for fault record
Ia instantaneous measurement angle for fault record
Vab instantaneous measurement primary for fault record
Ib instantaneous measurement secondary for fault record
Vbc instantaneous measurement primary for fault record
Ib instantaneous measurement angle for fault record
Vca instantaneous measurement primary for fault record
Ic instantaneous measurement secondary for fault record
V1 instantaneous measurement secondary for fault record
Ic instantaneous measurement angle for fault record
V1 instantaneous measurement angle for fault record
Ia instantaneous measurement primary for fault record
V2 instantaneous measurement secondary for fault record
Ib instantaneous measurement primary for fault record
V2 instantaneous measurement angle for fault record
Ic instantaneous measurement primary for fault record
V0 instantaneous measurement secondary for fault record
Iab instantaneous measurement secondary for fault record
V0 instantaneous measurement angle for fault record
Iab instantaneous measurement angle for fault record
V1 instantaneous measurement primary for fault record
Ibc instantaneous measurement secondary for fault record
V2 instantaneous measurement primary for fault record
Ibc instantaneous measurement angle for fault record
V0 instantaneous measurement primary for fault record
Ica instantaneous measurement secondary for fault record
Vs instantaneous measurement secondary for fault record
Ica instantaneous measurement angle for fault record
Vs instantaneous measurement angle for fault record
Iab instantaneous measurement primary for fault record
Vs instantaneous measurement primary for fault record
Ibc instantaneous measurement primary for fault record
Vs2 instantaneous measurement secondary for fault record
Ica instantaneous measurement primary for fault record
Vs2 instantaneous measurement angle for fault record
I1 instantaneous measurement secondary for fault record
Vs2 instantaneous measurement primary for fault record
I1 instantaneous measurement angle for fault record
Running voltage of SyncRy1 (VT secondary value)
I2 instantaneous measurement secondary for fault record
Running voltage of SyncRy1 (VT primary value)
I2 instantaneous measurement angle for fault record
Incoming voltage of SyncRy1 (VT secondary value)
I0 instantaneous measurement secondary for fault record
Incoming voltage of SyncRy1 (VT primary value)
I0 instantaneous measurement angle for fault record
Differential voltage of SyncRy1's VR and VI (VT secondary value)
I1 instantaneous measurement primary for fault record
Differential voltage of SyncRy1's VR and VI (VT primary value)
I2 instantaneous measurement primary for fault record
Running voltage of SyncRy2 (VT secondary value)
I0 instantaneous measurement primary for fault record
Running voltage of SyncRy2 (VT primary value)
Ie instantaneous measurement secondary for fault record
Incoming voltage of SyncRy2 (VT secondary value)
Ie instantaneous measurement angle for fault record
Incoming voltage of SyncRy2 (VT primary value)
Ie instantaneous measurement primary for fault record
Differential voltage of SyncRy2's VR and VI (VT secondary value)
Ie instantaneous measurement secondary for fault record
Differential voltage of SyncRy2's VR and VI (VT primary value)
Ie instantaneous measurement angle for fault record
Ie instantaneous measurement primary for fault record
DIFG-L Id0pu measurement secondary for fault record / metering
DIFG-L Id0pu measurement primary for fault record / metering
DIF-L Phase-A Idpu measurement secondary
DIF-L Phase-B Idpu measurement secondary
DIF-L Phase-C Idpu measurement secondary
DIF-L Phase-A Idpu measurement primary
DIF-L Phase-B Idpu measurement primary
DIF-L Phase-C Idpu measurement primary
Vab measurement secondary
Vbc measurement secondary
Vca measurement secondary
Ise measurement secondary