6F2S1914 (0.49)
GRL200 (Soft 033 & 037)
- 165 -
ZG (Function ID 431001
Setting items
Range
Unit
Contents
Default
Note
1A rating
5A rating
1A
5A
Z2G-LPBlk
Non / Block
-
Z2G leading phase operation block
Non
Z2G-TPMD
1P / 3P
-
Z2G trip mode, phase segregated trip or 3-
phase trip
3P
Z2G-ARCBlk
Non / Block
-
Autoreclose execution block by Z2G-trip
Block
Z2G-OCFS-EN
Off / On
-
Fail-safe OC for Z2G-trip
Off
OCF2G
0.02 - 5.00
0.10 -
25.00
A
Fail-safe OC operation level for Z2G-trip
0.20
1.00
Z2G-SOTF
Off / On
-
SOTF using Z2G
Off
Z3G
Z3G-Dir
Forward / Reverse /
NonDir
-
Z3G direction to protect
Forward
Mho
Z3G-Mho.Angle
30 - 90
deg
Z3G mho characteristic angle (for Mho)
85
Z3G-
Mho.Reach
0.10 -
500.00
0.01 -
100.00
-
Z3G mho reach (for Mho)
40.00
8.00
Z3G-MhoX.EN
Off / On
-
Z3G reactance reach use or not (for Mho)
Off
Z3G-X.Reach
0.10 -
500.00
0.01 -
100.00
-
Z3G reactance reach
40.00
8.00
Z3G-MhoR.EN
Off / On
-
Z3G resistive reach use or not (for Mho)
Off
Z3G-R.Angle
30 - 90
deg
Z3G resistive reach characteristic angle
75
Z3G-R.Reach
0.10 -
500.00
0.01 -
100.00
-
Z3G resistive reach
25.50
5.10
Z3G-DX.Angle
0 - 60
deg
Z3G directional-X characteristic angle
30
Z3G-
MhoDX.EN
Off / On
-
Z3G directional-X characteristic use or not (for
Mho)
Off
Quad
Z3G-X.Reach
0.10 -
500.00
0.01 -
100.00
-
Z3G reactance reach
40.00
8.00
Z3G-R.Angle
30 - 90
deg
Z3G resistive reach characteristic angle
75
Z3G-R.Reach
0.10 -
500.00
0.01 -
100.00
-
Z3G resistive reach
25.50
5.10
Z3G-DX.Angle
0 - 60
deg
Z3G directional-X characteristic angle
30
Z3G-DR.Angle
0 - 60
deg
Z3G directional-R characteristic angle (for
Quad)
5
I0K
Z3G-Krs
0 - 1000
%
Zero phase current factor, Self line R0/R1
100
Z3G-Kxs
0 - 1000
%
Zero phase current factor, Self line X0/X1
100
Z3G-Krm
0 - 1000
%
Zero phase current factor, Adjacent line
R0m/R1
0
Z3G-Kxm
0 - 1000
%
Zero phase current factor, Adjacent line
X0m/X1
0
TZ3G
0.00 - 100.00
s
Z3G operation delay time
0.40
Output
Z3G-EFL
Off / On
-
EFL operation condition used or not for Z3G
operation
On
Z3G-MPFBlk
Non / Block
-
Z3G operation block or not in multi phase fault
Non
Z3G-PSBBlk
Non / Block
-
Z3G operation block or not by PSB detection
Non
Z3G-LEBlk
Non / Block
-
Load encroachment enable
Non
Z3G-LPBlk
Non / Block
-
Z3G leading phase operation block
Non
Z3G-TPMD
1P / 3P
-
Z3G trip mode, phase segregated trip or 3-
phase trip
3P
Z3G-ARCBlk
Non / Block
-
Autoreclose execution block by Z3G-trip
Block
Z3G-OCFS-EN
Off / On
-
Fail-safe OC for Z3G-trip
Off
OCF3G
0.02 - 5.00
0.10 -
25.00
A
Fail-safe OC operation level for Z3G-trip
0.20
1.00
Z3G-SOTF
Off / On
-
SOTF using Z3G
Off
Z4G
Z4G-Dir
Forward / Reverse /
NonDir
-
Z4G direction to protect
Reverse
Mho
Z4G-Mho.Angle
30 - 90
deg
Z4G mho characteristic angle (for Mho)
85