H7 ASD Operation Manual 161
Position Difference Limit (Droop Pulses Allowed)
Program
⇒
Feedback Parameters
⇒
Feedback Settings
While operating in the Drooping Control mode, this parameter sets the
maximum allowed difference between the number of pulses that are detected
within the multiple-motor group.
Direct Access Number — F631
Parameter Type — Numerical
Factory Default — 16.0
Changeable During Run — No
Minimum — 0.1
Maximum — 6553
Release After Run Timer
Program
⇒
Protection Parameters
⇒
Brake Fault Timer
This parameter sets the time that the brake will hold after the Run command
criteria has been met.
Direct Access Number — F632
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — No
Minimum — 0.00
Maximum — 2.50
Units — Seconds
Acc/Dec Base Frequency Adjustment
Program
⇒
Terminal Selection Parameters
⇒
Analog Input Functions
This parameter Enables/Disables the feature that allows for the external
adjustment of the Base Frequency. When enabled, either VI/II or RR may be
used as an input source for the modification of the Base Frequency setting.
Settings:
Disabled
VI/II
RR
Direct Access Number — F650
Parameter Type — Selection List
Factory Default — Disabled
Changeable During Run — Ye s
Upper Limit Frequency Adjustment
Program
⇒
Terminal Selection Parameters
⇒
Analog Input Functions
This parameter Enables/Disables the feature that allows for the external
adjustment of the Upper Limit. When enabled, either VI/II or RR may be used
as an input source for the modification of the Upper Limit setting.
Settings:
Disabled
VI/II
RR
Direct Access Number — F651
Parameter Type — Selection List
Factory Default — Disabled
Changeable During Run — Ye s