H7 ASD Operation Manual 161
Position Difference Limit (Droop Pulses Allowed)
Program
Feedback Parameters
Feedback Settings
While operating in the Drooping Control mode, this parameter sets the
maximum allowed difference between the number of pulses that are detected
within the multiple-motor group.
Direct Access Number F631
Parameter Type Numerical
Factory Default 16.0
Changeable During Run — No
Minimum — 0.1
Maximum — 6553
Release After Run Timer
Program
Protection Parameters
Brake Fault Timer
This parameter sets the time that the brake will hold after the Run command
criteria has been met.
Direct Access Number F632
Parameter Type Numerical
Factory Default 0.00
Changeable During Run — No
Minimum — 0.00
Maximum — 2.50
Units — Seconds
Acc/Dec Base Frequency Adjustment
Program
Terminal Selection Parameters
Analog Input Functions
This parameter Enables/Disables the feature that allows for the external
adjustment of the Base Frequency. When enabled, either VI/II or RR may be
used as an input source for the modification of the Base Frequency setting.
Settings:
Disabled
VI/II
RR
Direct Access Number F650
Parameter Type Selection List
Factory Default Disabled
Changeable During Run — Ye s
Upper Limit Frequency Adjustment
Program
Terminal Selection Parameters
Analog Input Functions
This parameter Enables/Disables the feature that allows for the external
adjustment of the Upper Limit. When enabled, either VI/II or RR may be used
as an input source for the modification of the Upper Limit setting.
Settings:
Disabled
VI/II
RR
Direct Access Number F651
Parameter Type Selection List
Factory Default Disabled
Changeable During Run — Ye s
F631 F651
www . ElectricalPartManuals . com