90 H7 ASD Operation Manual
RR Torque Reference Setpoint #2 (%)
Program
Torque Setting Parameters
Setpoints
RR
This parameter is used to set the gain and bias of the RR input terminal when
this terminal is used as the control input while operating in the Torque Control
mode.
This is accomplished by establishing an associated V/f output pattern for a given
RR input level and motor load.
See F210 for further information on this setting.
This parameter sets RR Torque Reference Setpoint #2 and is the output torque
value that is associated with setting of F212. This value is entered as 0 – 250%
of the rated torque.
Direct Access Number F215
Parameter TypeNumerical
Factory Default100.0
Changeable During Run — Yes
Minimum — 0.0
Maximum — 250.0
Units — %
F215 F215