27
HWS-1403XWHM3-E, T6-E, D6-E, T9-E
O·········Applied
OP·······Optional accessory
No. Component name
Model name
Type name Rating
M3-E T6-E D6-E T9-E
1
Circulating pump
OOOO
UPS25-80 130 AC230 V 0.83 A (MAX)
2
Backup heater 6 kW
OOO
AC 400 V (3N) 6 kW (AC230 V 3kW
compatible)
3
Backup heater 9 kW
O–
AC 400 V (3N) 9 kW
4
Water heat exchange
temperature sensor
(TC sensor)
OOOO
10 kΩ (25°C)
5
Water inlet temperature sensor
(TWI sensor)
OOOO
10 kΩ (25°C)
6
Water outlet temperature sensor
(TWO sensor)
OOOO
10 kΩ (25°C)
7
Heater outlet water temperature
sensor
(THO sensor)
OOOO
10 kΩ (25°C)
8
Floor inlet temperature sensor
(TFI sensor)
OOOO
10 kΩ (25°C)
9
Pressure switch
OOOO
Operating pressure 4.15 MPa +0 -0.3
MPa
10
Low pressure sensor
OOOO
Operating pressure 0.20 MPa
11
Thermal protector (auto)
OOOO
Operating temperature 75±3°C DC42 V
/ 0.2 A
12
Thermal protector (single
operation)
OOOO
Operating temperature 95±5°C AC250
V 16 A
13
Flow switch
OOOO
Operating flowing quantity 17.5 L/min
14
Output board (OP)
OP OP OP OP
TCB-PCIN3E AC230 V 0.5 A DC24 V 1 A
15
Input board (OP)
OP OP OP OP
TCB-PCM03E Contact input
16
Remote control (Main)
OOOO
HWS-AMS11E
17
Remote control (Sub)
OP OP OP OP
HWS-AMS11E
18
Water 3-way valve terminal
OOOO
AC230 V 0.1 A
2Wire, 3Wire SPST, SPDT type
mountable
19
Water 2-way valve terminal
OOOO
AC230 V 0.1 A 2Wire type mountable
20
Mixing valve terminal
OOOO
AC230 V 0.1 A
3Wire SPST, SPDT type mountable
21
Circulating pump terminal
OOOO
AC230 V 1.0 A
22
Booster heater terminal
OOOO
AC230 V 1.0 A
23
Fuse
OOOO
AC 250 V 30 A

Table of Contents