167
9. OWNER’S MANUAL
Engineering Data book
2 NAMES AND FUNCTIONS OF PARTS
Buttons
NOTE
Some functions are not provided depending on the
system specifications in use.
For details, contact the installation company.
17
16
1
10
2
3
4
76
89 11
12
15
14
13
5
Fig. 2-01
1. TEMP. button:
Changes the set temperature for
each operation mode (ZONE1/2
hot water) by 1°C step.
2. SCHEDULE
button:
Sets the current time and
scheduled weekly operation.
3. TIME button:
Changes time for current time
setting and scheduled weekly
operation setting with and
buttons.
4. SET button:
Determines the entered current
time setting and scheduled weekly
operation setting.
5. CL button:
Clears settings for the current time
and scheduled weekly operation.
Cancels audible alarm in the event
of a system fault.
6. DAY button:
Sets days of the week for current
time setting and scheduled weekly
operation setting.
7. STEP button:
Specifies switching STEP number
in a day for weekly schedule.
8. TEST button:
Used for test run or service.
9. FROST
PROTECTION
button:
Controls minimum operation for
unused period (going out, absence,
etc.) for anti freezing.
10. NIGHT button:
Controls the night set back
operation.
11. AUTO TEMP.
button:
Switches setting temperature
automatically according to outside
temperature. (Pressing this button
long changes the mode to data
setting mode.)
12. OPERATE MODE
button: Selects ZONE1/2 operation mode
(heating or cooling).
13. ZONE1, 2 button:
Turns on/off the zone (floor
heating/radiator/Fan Coil Unit)
operation.
14. ANTI BACTERIA
button:
Regularly increases the hot water
temperature in the tank for
sterilization. (Pressing this button
long changes the mode to data
setting mode.)
15. HOT WATER
BOOST button:
Boosts boiling when high tapping
temperature is required
temporarily.
16. HOT WATER
button:
Turns on/off hot water operation.
17. SELECT button:
Selects an operation mode when
changing the set temperature of
each operation mode.