EasyManua.ls Logo

Toshiba HWS-803XWHM3-E - Page 26

Toshiba HWS-803XWHM3-E
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Toshiba XXXXXXX(<SanSerif1>X/X)
–26–
Hydro Unit
Installation Manual
Electrical Connection (Hot Water Cylinder
temperature Sensor)
Connect the hot water cylinder temperature sensor
as shown below to terminals A & B on Terminal
Block 06 in the Hydro Unit.
Please ensure that the interconnecting cable,
between the Hydro Unit and the hot water cylinder, is
connected to earth at both ends of the cable using
the shield wire.
Fig. 7-31
Additional hydro unit outputs
Alarm and Boiler Outputs
Alarm Output: L1: Alarm output
Output enabled when the system is in alarm/fault
condition.
Volt free contact - specification shown below:
AC230 V; 0.5 A (maximum)
DC24 V; 1 A (maximum)
Connection details: Terminals 1 and 2
(OPERATION) on MCC-1217 TB (Refer to “Fig. 7-
32”)
Boiler Control Output: L2: Boiler drive permission
output
Output enabled when outdoor ambient temperature
<-10°C
Volt free contact - specification shown below:
AC230 V; 0.5 A (maximum)
DC24 V; 1 A (maximum)
Connection details: Terminals 3 and 4 (EMG) on
MCC-1217 TB (Refer to “Fig. 7-32”)
Fig. 7-32
Defrost and Compressor operation Outputs
Defrost output
Display relay is ON when the system defrost.
Volt free contact
AC230 V; 0.5 A (maximum)
DC24 V; 1 A (maximum)
Connection details: Terminals 1 and 2
(OPERATION) on MCC-1217 TB (Refer to “Fig. 7-
33”)
PJ20
CN208
TCB-PCIN3E
4
3
L2
2
1
L1
+00EF99805101_01EN.book Page 26 Monday, June 21, 2010 3:45 PM

Other manuals for Toshiba HWS-803XWHM3-E

Related product manuals