– 27 –
Hydro Unit
Installation Manual
Service monitor
The sensor sensing temperature is displayed on the
remote controller.
This function allows you to make sure whether the
sensor is installed properly.
(1) Press the [ ] / [ ] button to select
“Service monitor” on the “FIELD SETTING MENU”
screen, then press the [
] button.
(2) Press the [ ] button to select the unit, then press
the [ ] button to display the status.
Some sensors (temperature / pressure) are not
displayed, because not connected.
Service monitor
FIELD SETTING MENU(2/2)
Hydro Unit DN
Remote controller DN
Reset power consumption data
Sensor information
SET
Service monitor
1 - 1
1 - 4
1 - 2
1 - 3
1 - 5
1 - 6
1 - 7
1 - 8
SET
UNIT
Service monitor
Code Data
RETURN
Hydro Unit data
code Data name Unit
00 Control temperature (Hot water cylinder) °C
01 Control temperature (Zone1) °C
02 Control temperature (Zone2) °C
03 Remote controller sensor temperature °C
04 Condensed temperature (TC) °C
06 Water inlet temperature (TWI) °C
07 Water outlet temperature (TWO) °C
08 Water heater outlet temperature (THO) °C
09 Floor inlet temperature (TFI) °C
0A Hot water cylinder temperature (TTW) °C
0B Mixing valve position step
0E Low pressure (Ps) × 1/10 kPa
0F Hydro soft ver. -
Outdoor Unit data
code Data name Unit
60 Heat exchange temperature (TE) °C
61 Outside air temperature (TO) °C
62 Discharge temperature (TD) °C
63 Suction temperature (TS) °C
65 Heat sink temperature (THS) °C
6A Current × 10 A
6D Heat exchanger coil temperature (TL) °C
70 Compressor operation Hz Hz
72
Number of revolutions of outdoor fan
(lower or 1 fan model)
rpm
73
Number of revolutions of outdoor fan
(upper)
rpm
74 Outdoor PMV position × 1/10 pls
7A Discharge pressure (PD) × 1/10 kPa
Service unit data
code Data name Unit
F0
Micro computer energized accumulation
time × 1/100
h
F1
Hot water compressor ON accumulation
time × 1/100
h
F2
Cooling compressor ON accumulation
time × 1/100
h
F3
Heating compressor ON accumulation
time × 1/100
h
F4
Built-in AC pump operation
accumulation time × 1/100
h
F5
Hot water cylinder heater operation
accumulation time × 1/100
h
F6
Backup heater operation accumulation
time × 1/100
h
F7
Booster heater operation accumulation
time × 1/100
h
Reset power consumption
data
(1) Press the [ ] / [ ] button to select “Reset
power consumption data” on the “FIELD SETTING
MENU” screen, then press the [
] button.
(2) Press the [ ] button, then power consumption
data is cleared.
Sensor information
(1) Press [ ] / [ ] button to select “Sensor
information” on the “FIELD SETTING MENU”
screen, then press the [
] button.
(2) Select display number.
Display 1 is Hydro Unit sensor
Display 2 is Outdoor Unit sensor
Service monitor
FIELD SETTING MENU(2/2)
Hydro Unit DN
Remote controller DN
Reset power consumption data
Sensor information
SET
Reset power consumption data
NOYES
Do you want to reset data?
Service monitor
FIELD SETTING MENU(2/2)
Hydro Unit DN
Remote controller DN
Reset power consumption data
Sensor information
SET
Sensor information(1/2)
NOYES
TC 30°C
TWI 30°C
TWO 35°C
THO 35°C
WF 23.0 L/min
LPS 1.2MPa
TTW 45°C
TFI 30°C
RT 20°C
MIX 10step
RETURN
NOYES
Sensor information(2/2)
TO 16°C
TD 80°C
TE 12°C
TS 15°C
CT 15.0A
CMP 90Hz
FAN1 600rpm
FAN2 600rpm
PMV 250pls
HPS 4.0MPa
RETURN
53-EN 54-EN