Technical parameters for heat pump combination heater
Climate condition : average climate
Models:
Outdoor unit HWT-801H(R)W-E HWT-1101H(R)W-E HWT-1401H(R)W-E
Indoor unit
HWT-1101XWHM3W-E
HWT-1101XWHM6W-E
HWT-1101XWHT6W-E
HWT-1101XWHT9W-E
HWT-1401XWHM3W-E
HWT-1401XWHM6W-E
HWT-1401XWHT6W-E
HWT-1401XWHT9W-E
Hot water cylinder (HWS-***1CSHM3-E) ***⇒ 150 210 300 150 210 300 150 210 300
Air-to-water heat pump: yes yes yes
Water-to-water heat pump: no no no
Brine-to-water heat pump: no no no
Low-temperature heat pump: no no no
Equipped with a supplementary heater: no no no
Heat pump combination heater: yes yes yes
Parameters for Low-temperature application/ Medium-temperature
application
Medium Medium Medium
Symbol Unit Value
Item
Rated heat output (*) P
rated
kW 8 8 11
Seasonal space heating energy
efficiency
η
s
% 142 142 138
Declared
capacity for
heating for
part load
at indoor
temperature
20 °C and
outdoor
temperature
Tj
Tj = - 7 °C Pdh kW 7.3 7.3 9.9
Tj = +2 °C Pdh kW 4.6 4.5 6.2
Tj = + 7 °C Pdh kW 3.0 3.0 3.9
Tj = + 12 °C Pdh kW 2.3 2.3 4.2
Tj = bivalent
temperature
Pdh kW 7.3 7.3 9.9
Tj = operation limit
temperature
Pdh kW 6.7 6.7 9.4
Tj = - 15 °C
(if TOL < - 20 °C)
Pdh kW - - -
Bivalent temperature T
biv
°C -7 -7 -7
Cycling interval capacity for heating P
cych
kW - - -
Degradation co-efficient (**) C
dh
- 0.9 0.9 0.9
Declared
coefficient of
performance
or primary
energy ratio
for part load
at indoor
temperature
20 °C and
outdoor tem-
perature Tj
Tj = - 7 °C COPd - 2.12 2.12 2.21
Tj = +2 °C COPd - 3.60 3.58 3.34
Tj = + 7 °C COPd - 4.75 4.75 4.76
Tj = + 12 °C COPd - 7.00 7.00 7.27
Tj = bivalent
temperature
COPd - 2.12 2.12 2.21
Tj = operation limit
temperature
COPd - 1.90 1.89 2.01
Tj = - 15 °C
(if TOL < - 20 °C)
COPd - - - -
Operation limit temperature TOL °C -10 -10 -10
Cycling interval efficiency P
cych
- - - -
Heating water operating limit
temperature
WTOL °C 65 65 65
Power
consumption
in modes other
than active
mode
Off mode P
OFF
kW 0.007 0.007 0.011
Thermostat-off mode P
TO
kW 0.049 0.049 0.052
Standby mode P
SB
kW 0.007 0.007 0.011
Crankcase heater mode P
CK
kW 0.000 0.000 0.000
Supplementary
heater
Rated heat output (*) P
sup
kW 1.3 1.3 1.7
Type of energy input 220-240V ~,50Hz 220-240V ~,50Hz 220-240V ~,50Hz
Other items Capacity control variable variable variable
Sound power level, indoors/
outdoors
LWA dB 40/65 40/65 40/62
Rated air flow rate, outdoors - m
3
/h 3142 3506 4720
For heat pump
combination
heater:
Declared load profile - - L XL XL L XL XL L XL XL
Daily electricity consumption Qelec kWh 4.616 6.743 7.040 4.616 6.743 7.040 4.391 7.348 7.516
Water heating energy efficiency ηwh % 106 118 113 106 118 113 112 107 106
contact details : ToshibaCarrierAir-conditioningEuropeSp.zo.o.,ul.Gdańska131,62-200Gniezno,Poland
(*) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating
Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).
(**) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
Technical parameters for heat pump combination heater
Climate condition : average climate
Models:
Outdoor unit HWT-401HW-E HWT-601HW-E
Indoor unit
HWT-601XWHM3W-E
HWT-601XWHM6W-E
HWT-601XWHT6W-E
Hot water cylinder (HWS-***1CSHM3-E) ***⇒ 150 210 300 150 210 300
Air-to-water heat pump: yes yes
Water-to-water heat pump: no no
Brine-to-water heat pump: no no
Low-temperature heat pump: no no
Equipped with a supplementary heater: no no
Heat pump combination heater: yes yes
Parameters for Low-temperature application/ Medium-temperature application Medium Medium
Symbol Unit Value
Item
Rated heat output (*) P
rated
kW 5 6
Seasonal space heating energy efficiency η
s
% 135 132
Declared
capacity for
heating for
part load
at indoor
temperature
20 °C and
outdoor
temperature Tj
Tj = - 7 °C Pdh kW 4.0 5.0
Tj = +2 °C Pdh kW 2.5 3.4
Tj = + 7 °C Pdh kW 1.6 2.0
Tj = + 12 °C Pdh kW 1.5 1.5
Tj = bivalent
temperature
Pdh kW 4.0 5.0
Tj = operation limit
temperature
Pdh kW 3.5 4.5
Tj = - 15 °C
(if TOL < - 20 °C)
Pdh kW - -
Bivalent temperature T
biv
°C -7 -7
Cycling interval capacity for heating P
cych
kW - -
Degradation co-efficient (**) C
dh
- 0.8 0.8
Declared
coefficient of
performance
or primary
energy ratio
for part load
at indoor
temperature
20 °C and
outdoor
temperature Tj
Tj = - 7 °C COPd - 2.18 2.10
Tj = +2 °C COPd - 3.48 3.22
Tj = + 7 °C COPd - 4.28 4.58
Tj = + 12 °C COPd - 6.35 6.35
Tj = bivalent
temperature
COPd - 2.18 2.10
Tj = operation limit
temperature
COPd - 1.83 1.81
Tj = - 15 °C
(if TOL < - 20 °C)
COPd - - -
Operation limit temperature TOL °C -10 -10
Cycling interval efficiency P
cych
- - -
Heating water operating limit temperature WTOL °C 55 55
Power
consumption in
modes other than
active mode
Off mode P
OFF
kW 0.008 0.008
Thermostat-off mode P
TO
kW 0.040 0.040
Standby mode P
SB
kW 0.008 0.008
Crankcase heater mode P
CK
kW 0.008 0.008
Supplementary
heater
Rated heat output (*) P
sup
kW 1.5 1.5
Type of energy input 220-240V ~,50Hz 220-240V ~,50Hz
Other items
Capacity control variable variable
Sound power level, indoors/outdoors L
WA
dB 40/65 40/65
Rated air flow rate, outdoors - m
3
/h 2015 2015
For heat pump
combination
heater:
Declared load profile - - L L XL L L XL
Daily electricity consumption Q
elec
kWh 4.061 4.289 6.506 4.061 4.289 6.506
Water heating energy efficiency η
wh
% 120 115 122 120 115 122
contact details : ToshibaCarrierAir-conditioningEuropeSp.zo.o.,ul.Gdańska131,62-200Gniezno,Poland
(*) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating
Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).
(**) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
75-EN
76-EN