150
2-3. How to reset hydro DN
(1) Procedure
1) Proceed the hydro DN setting screen. * See 9-2-1. Hydro DN setting
2) Press the
[ ] [ ] [ ] long time in DN setting screen, and select “YES”.
NOTE
After DN reset, it will take few minutes to back normal screen. First communication screen will continue for few
minutes, but it is NOT trouble.
After DN reset, it is necessary to confirm and set again some item below.
2-4. How to reset remote controller DN
(1) Procedure
1) Proceed the remote controller DN setting screen. * See 9-2-2. Remote controller DN setting
2) Press the
[ ] [ ] [ ] long time in DN setting screen, and select "YES".
DN Item Details Factory default
11 Water heat exchanger capacity 0010: 601 0015: 1101 Depend on type
6B8 Hot water supply is using 0000: Yes 0001: No 0000: Yes
6BA ZONE2 operation is using 0000: No 0001: Yes 0000: No
6BC Back up heater capacity 0000: 3 kW
0002: 9 kW
0001: 6 kW Depend on type