116
[A13] [A14] Pump error
Input appropriate voltage
Restart after resolve the cause
Yes
Yes
Yes
Start
No
No
No
Resolve the cause
0700 Duty 0980
during pump operation
* Service monitor code: CF
Pump power input has
AC 220-240 V
Power terminal has
AC 220-240 V(±10%)
High humidity around
the electric board of the
pump
Yes
No
Resolve the cause
Dew condensation to
the electric board of the
pump
Yes
Yes
No
Resolve the cause
Locking by a certain
cause
Yes
No
Replace the pump
Pump error occurring
again
Check water
heat exchange
control board
If defective, replace it
PC board
MCC-1753
MCC-1755

Table of Contents