118
[F04] TD sensor error
[F06] TE sensor error
[F07] TL sensor error
Correct TD sensor
connection
Replace TD sensor
No
No
TD sensor
connector (*) is
connected
Yes
TD sensor
resistance characteristic
is normal
Yes
Start
Check outdoor control board
If defective, replace it
PC board
<401, 601> MCC-1768
<801, 1101> MCC-1675
(Refer to Characteristic table on page 137)
* 401, 601 = CN601
801, 1101 = CN603
Correct TE sensor
connection
Replace TE sensor
No
No
TE sensor
connector (*) is
connected
Yes
TE sensor
resistance characteristic
is normal
Yes
Start
Check outdoor control board
If defective, replace it
PC board
<401, 601> MCC-1768
<801, 1101> MCC-1675
(Refer to Characteristic table on page 137)
* 401, 601 = CN600
801, 1101 = CN601
Correct TL sensor
connection
Replace TL sensor
No
No
TL sensor
connector (CN604) is
connected
Yes
TL sensor
resistance characteristic
is normal
Yes
Start
Check outdoor control board
If defective, replace it
PC board
<401, 601> MCC-1768
<801, 1101> MCC-1675
(Refer to Characteristic table on page 137)