169
• Some sensors (temperature / pressure) or fan are not displayed, because not connected.
Hydro unit data
Item code Data name Unit
00 Target temperature for hot water supply °C
01 Target water temperature for Zone1 °C
02 Target water temperature for Zone2 °C
03 Remote controller sensor temperature °C
04 Condensed temperature (TC) °C
06 Water inlet temperature (TWI) °C
07 Water outlet temperature (TWO) °C
08 Water heater outlet temperature (THO) °C
09 Floor inlet temperature (TFI) °C
0A Hot water cylinder temperature (TTW) °C
0B Mixing valve position step
0E Low pressure (Ps) × 1/10 kPa
0F Hydro soft Ver. ‒
10 Control temperature (Hot water cylinder) °C
11 Control temperature (Zone1) °C
12 Control temperature (Zone2) °C
Outdoor unit data
Item code Data name Unit
60 Heat exchange temperature (TE) °C
61 Outside air temperature (TO) °C
62 Discharge temperature (TD) °C
63 Suction temperature (TS) °C
65 Heat sink temperature (THS) °C
6A Current × 10 A
6D Heat exchanger coil temperature (TL) °C
70 Compressor operation Hz Hz
72 Number of revolutions of outdoor fan (lower or 1 fan model) rpm
73 Number of revolutions of outdoor fan (upper) rpm
74 Outdoor PMV position × 1/10 pls
Service data
Item code Data name Unit
F0 Micro computer energized accumulation time × 1/100 h
F1 Hot water compressor ON accumulation time × 1/100 h
F2 Cooling compressor ON accumulation time × 1/100 h
F3 Heating compressor ON accumulation time × 1/100 h
F4 Built-in circulation pump operation accumulation time × 1/100 h
F5 Hot water cylinder heater operation accumulation time × 1/100 h
F6 Backup heater operation accumulation time × 1/100 h
F7 Booster heater operation accumulation time × 1/100 h