EasyManua.ls Logo

Toshiba IK-TU51CU - Menus; SHUTTER (Electronic Shutter)

Toshiba IK-TU51CU
53 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.
2
Menus
Select
the
menu
to
change
the
setting
by
referring
the
item
“7.1
Using
the
Menus”.)
When
the
[MENU
UP],
[MENU
DOWN]
buttons
are
pushed,
the
“—”
on
the
screen
moves
up
and
down.
Move
the
“—”
to
the
item
to
change.
(11
SHUTTER
(Electronic
shutter)
The
electronic
shutter
has
four
modes;
AUTO,
MANUAL,
SS(Synchro.
Scan),
EXT
TRIG(External
trigger).
Press
the
“Page”
button
to
enter
the
Shutter
Page.
Use
the
“Data
Up/Down”
buttons
to
select
the
Shutter
Mode.
j-»
AUTO*—*
MANUAL**—
SS^—
E
XT
TRIG
n
AUTO
MANUAL
SS
EXT
TRIG
The
exposure
time
is
controlled
automatically
to
obtain
the
video
level
set.
It
is
possible
to
select
the
exposure
time
from
eight
speed
settings;
OFF
(1/60s),
1/100s,
1/250S,
1/500S,
1/1000s,
1/2000S,
IMOOOs,
1/IOOOOs.
Note:
When
setting
a
rapid
shutter
speed,
sensitivity
degrades
according
to
the
speed.
When
a
discharging
light
such
as
fluorescent
lamp,
etc.
is
used
for
the
illumination,
the
flicker
may
be
large.
Shutter
speed
can
be
set
by
the
horizontal
scanning
time
(1H)
unit
or
by
the
frame
unit.
Exposure
is
performed
and
images
are
output
by
external
trigger.
EXT
TRIG
includes
the
four
modes
described
below.
(For
details
of
specifications,
refer
to
the
item
“7.5
EXT
TRIG
(External
trigger)”.)
•1
PULSE
SNR(1
Pulse
Sync
Non
Reset)
The
charge
begins
to
accumulate
after
the
trigger
pulse
is
received,
and
1
field
images
are
output
according
to
the
internal
vertical
sync
signal
timing.
The
exposure/accumulation
time
can
be
set
from
0.06
to
16
ms.
The
trigger
signal
timing
can
be
set
to
either
the
rising
or
falling
edge.
1
PULSE
SR(1
Pulse
Sync
Reset)
The
charge
begins
to
accumulate
after
the
trigger
pulse
is
received.
Upon
completion
of
accumulation
the
vertical
sync
signal
is
reset
and
1
field
images
are
output.
The
exposure/accumulation
time
can
be
set
from
0.06
to
16
ms.
The
trigger
signal
timing
can
be
set
to
either
the
rising
or
falling
edge.
•2
PULSE
The
charge
begins
to
accumulate
after
the
trigger
pulse
is
received.
Upon
completion
of
accumulation
the
vertical
sync
signal
is
reset
and
1
fieid
images
are
output.
The
exposure/accumulation
time
is
the
time
from
when
the
first
trigger
signal
is
taken
in
until
the
next
trigger
signal
is
taken
in.
The
trigger
signal
intake
timing
can
be
set
to
one
of
three
settings:
rising
edge,
falling
edge
or
pulse
width
(front
and
back
edges
of
pulse).
•RS232C
Accumulation
of
charges
is
started
and
ended
by
RS232C
external
control
command
input,
and
1
field
images
are
output
without
changing
the
vertical
sync
signal
timing.
19

Table of Contents

Related product manuals