7.
5
EXT
TRIG
(External
trigger)
Charge
begins
to
accumulate
after
the
trigger
input
operation
(in
the
RS232C
mode,
by
RS232C
command
input,
in
other
modes,
by
trigger
pulse
(TRIGGER)
input
to
the
DC
IN/SYNC
terminal)
or
trigger
signal
input
to
the
DIGITAL
terminal
and
1
field
or
1
frame
images
are
output.
There
are
four
modes:
1
PULSE
SNR,
1
PULSE
SR,
2PULSE
and
RS232C.
The
DC
IN/SYNC
terminal
trigger
input
and
index
output
interface
are
as
shown
below.
5V
150Q
(CMOS
out)
—-^AAA-
1INDEX
out
|
(1)
1
PU
L
SE
SNR(1
Pulse
Sync
Non
Reset)
Charge
begins
to
accumulate
after
the
trigger
input
operation
to
the
DC
IN/SYNC
terminal
or
trigger
signal
input
(LVDS)
to
the
DIGITAL
terminal
and
1
field
images
are
output.
The
exposure
time
is
set
to
0.06
to
16
ms
on
the
menu.
Trigger
pulse
level
:
(Low
Level):
Less
than
0.5V
,
(High
Level):
3.4V
to
5V
(DC
IN/SYNC
terminal)
Trigger
pulse
fetch
timing
Trigger
pulse
width
Trigger
pulse
interval
Rising
edge
/
Falling
edge
selectable
More
than
2
//
s
More
than
50ms
A
picture
is
output
at
the
first
field
after
the
end
of
the
exposure.
@
.'
Camera
through
picture
0
:
Memory
picture
43

Table of Contents