3.9 ASYNC TestASYNC Test 3 Tests and Diagnostics
Portege 2000 Maintenance Manual (960-333) 3-21
3.9 ASYNC Test
To execute the ASYNC Test, select 7-ASYNC TEST from the DIAGNOSTIC TEST
MENU, press Enter, and follow the directions on the screen. The ASYNC Test contains one
subtests that test the ASYNC functions.
Move the highlight bar to the subtest you want to execute and press Enter.
The following shows the subtest 06 format.
System Asynchronous
Speed: 9600BPS
Data: Eight data bits and one parity bit (Even parity)
Data pattern From 20h to 7Eh
Subtest 06 FIR/SIR Point to Point (send)
CAUTION: This test needs to access from the computer to the other computer infrared
port.
Send from 20h to 7Eh data to the other by using FIR/SIR port and compare
original data with data received from the other computer.