Direct Access Parameter Information
Q9 Plus ASD Install/Op Manual
RX Input Point 2 Rate
Program Torque Setpoints
This parameter is used to set the gain and bias of the RX input
terminal when the RX terminal is used as the control input while
operating in the Torque Control mode.
Torque Control is accomplished by establishing an associated V/f
output pattern for a given RX input level.
This parameter sets RX Input Point 2 Rate and is the output
torque value that is associated with the setting of RX Input Point
2 Setting when operating in the Torque Control mode.
This value is entered as -250% to +250% of the rated torque.
See RX Input Point 1 Rate (F220) for additional information on
this parameter.
Direct Access Number
F221
Parameter Type — Numerical
Factory Default — 100.00
Changeable During Run — Yes
Minimum — -250.00
Maximum — +250.00
Units — %