9
How to remove the drain hose
• The drain hose can be removed by removing the
screw securing the drain hose and then pulling out
the drain hose.
• Whenremovingthedrainhose,becarefulofany
sharpedgesofsteelplate.Theedgescaninjuries.
• Toinstallthedrainhose,insertthedrainhose
firmly until the connection part contacts with heat
insulator,andthensecureitwithoriginalscrew.
How to remove the drain cap
Clip the drain cap by needle-nose
pliers and pull out.
How to fix the drain cap
1) Insert hexagon wrench (4 mm)
in a center head.
2) Firmly insert the drain cap.
Drain hose
No gap
Slit
Slit
Insert a hexagon wrench
(4 mm).
Do not apply lubricating oil
(refrigerant machine oil)
when inserting the drain
cap. Application causes
deterioration and drain
leakage of the plug.
Firmlyinsertthedrainhoseanddraincap;otherwise,watermayleak.
• After scribing slits inside of the
front-panel with a knife or a
making-opin,cutthemwithapair
of nippers or an equivalent tool.
• After scribing slits inside of the
front-panel with a knife or a
making-opin,cutthemwithapair
of nippers or an equivalent tool.
• Bend the connecting pipe so that it is laid within 43 mm above the wall
surface. If the connecting pipe is laid exceeding 43 mm above the wall
surface,theindoorunitmayunstablybesetonthewall.
Whenbendingtheconnectingpipe,makesuretouseaspringbenderso
as not to crush the pipe.
Bend the connecting pipe within a radius of 30 mm.
Toconnectthepipeafterinstallationoftheunit(gure)
In case of right or left piping
In case of bottom right or bottom left piping
Left-hand connection with piping
(To the forefront of flare)
Outward form of indoor unit
Usethehandleofscrewdriver,etc.
R 30 mm (Use polisin (polyethylene)
core or the like for bending pipe.)
Gas side
Liquid side
260 mm
43 mm
80°
210 mm
Ifthepipeisbentincorrectly,theindoorunitmayunstablybesetonthewall.
Afterpassingtheconnectingpipethroughthepipehole,connectthe
connecting pipes to the auxiliary pipes and wrap the facing tape around them.
• Bind the auxiliary pipes (two) and connecting cable with facing tape
tightly.Incaseofleftwardpipingandrear-leftwardpiping,bindthe
auxiliary pipes (two) only with facing tape.
Connecting cable
Indoor unit
Auxiliary pipes
Installation plate
• Carefully arrange pipes so that any pipe does not stick out of the rear
plate of the indoor unit.
• Carefully connect the auxiliary pipes and connecting pipes to one
anotherandcutotheinsulatingtapewoundontheconnectingpipe
toavoiddouble-tapingatthejoint;moreover,sealthejointwiththe
vinyltape,etc.
• Sincedewingresultsinamachinetrouble,makesuretoinsulateboth
connecting pipes. (Use polyethylene foam as insulating material.)
• Whenbendingapipe,carefullydoit,nottocrushit.
EN
Piping and Drain Hose Installation
* Sincedewingresultsinamachinetrouble,makesuretoinsulateboth
connecting pipes. (Use polyethylene foam as insulating material.)
Piping and drain hose forming
Rear right
Rear left
Bottom left
Left
Bottom right
Right
Die-cutting
front panel slit
Changing
drain hose
Piping preparation
1. Die-cutting front panel slit
Cut out the slit on the left or right side of the front panel for the left or right
connection and the slit on the bottom left or right side of the front panel
for the bottom left or right connection with a pair of nippers.
2. Changing drain hose
Forleftwardconnection,bottom-leftwardconnectionandrear-leftward
connection’spiping,itisnecessarytochangethedrainhoseanddraincap.
1
2
Indoor Unit Fixing
1. Pass the pipe through the hole in the wall and hook the indoor unit on the
installation plate at the upper hook.
2. Swingtheindoorunittorightandlefttoconrmthatitisrmlyhookedup
on the installation plate.
3. Whilepressingtheindoorunitontothewall,hookitatthelowerparton
theinstallationplate.Pulltheindoorunittowardyoutoconrmthatitis
rmlyhookedupontheinstallationplate.
Hook here
Hook
Push
Press
(unhook)
1
Installation plate
• For detaching the indoor unit
fromtheinstallationplate,
pull the indoor unit toward
you while pushing its bottom
upatthespeciedparts.
Push