EasyManua.ls Logo

Toshiba RAS-05E2KVG-TR - Electrical Works; Wiring Connection

Toshiba RAS-05E2KVG-TR
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
EN
ELECTRICAL WORKS
The power supply can be selected to connect to indoor unit or outdoor unit. Choose proper way and connect the power supply and connecting cable by follow
the instruction as following.
Model RAS-05E2KVG-TR RAS-07E2KVG-TR RAS-10E2KVG-TR RAS-13E2KVG-TR RAS-16E2KVG-TR RAS-18E2KVG-TR
Power source 50Hz,220–240VTekfazlı
Maximum running current 5.0A 5.4A 7.2A 7.4A 9.0A 9.25A
Circuit breaker rating 10A 15A 15A 15A 15A 15A
Power supply cable
H07RN-F or 60245
IEC66
(0.75 mm
2
or more)
H07RN-F or 60245 IEC66 (1.25 mm
2
or more)
H07RN-F or 60245
IEC66
(1.5 mm
2
or more)
Connecting cable H07RN-F or 60245 IEC66 (0.75 mm
2
or more)
Wiring Connection
Wiring of the connecting cable can be carried out without removing
the front panel.
1. Remove the air inlet grille.
Open the air inlet grille upward and pull it toward you.
2. Remove the terminal cover and cord clamp.
3. Insert the connecting cable (according to the local cords) into the pipe
hole on the wall.
4. Take out the connecting cable through the cable slot on the rear panel so
that it protrudes about 20 cm from the front.
5. Insert the connecting cable fully into the terminal block and secure it
tightly with screws.
6. Tighteningtorque:1.2N·m(0.12kgf·m)
7. Secure the connecting cable with the cord clamp.
8. Fixtheterminalcover,rearplatebushingandairinletgrilleonthe
indoor unit.
1. Removethevalvecover,theelectricpartscoverandthecordclampfrom
the outdoor unit.
2. Connecttheconnectingcabletotheterminalasidentiedbythe
matching numbers on the terminal block of indoor and outdoor unit.
3. Insert the power cord and the connecting cable carefully into the terminal
block and secure it tightly with screws.
4. Usevinyltape,etc.toinsulatethecordswhicharenotgoingtobeused.
Locate them so that they do not touch any electrical or metal parts.
5. Secure the power cord and the connecting cable with the cord clamp.
6. Attach the electric parts cover and the valve cover on the outdoor unit.
• Whenattachingtheairinletgrille,thecontraryoftheremovedoperationis
performed.
Indoor unit
Outdoor unit
How to install the air inlet grille on the
indoor unit
Front panel
Air inlet grille
Screw
Screws
Cord clamp
Terminal cover
Terminals block
Valve cover
1144180111-00_S04_182x257_40p_S_p70_220321.indd 13 22/03/21 8:19:38 AM