6
Fortherearleft,bottomleftandleftpiping
Cut out a piece of SPACER from indoor
unitpackagingbox,rollitandinsert
between the indoor unit and wall to tilt
the indoor unit for better operation.
Insulate the refrigerant pipes separately
withinsulation,nottogether.
Refrigerant piping
must be protected from
physical damage.
Install a plastic cover
or equivalent.
INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS
The auxiliary piping can be connected to
theleft,rearleft,rearright,right,bottom
right or bottom left.
Do not allow the drain hose to get slack.
Make sure to run the drain hose sloped
downward.
Hook
Hook
Airller
5
Filter
0
Flat head
wood screw
7
Flat head
wood screw
4
Remote control
holder
2
Wireless remote
control
Batteries
3
Flat head
wood screw
7
Battery
cover
!
(Attach to the front panel.)
1
Installation
plate
The provided Remote Controller is a wireless
type,whichalsocanbeusedasawire.
Please see “How to Connect The Remote
ControllerforWiredOperation”,incaseof
wired control is required.
Extension drain hose
(Notavailable,provided
by installer)
Vinyl tape
Apply after carrying
out a drainage test.
Shield pipe
Right
Saddle
E mm or more
C mm or more
65 mm or more
D mm or more
F mm or more
C mm or more
300 mm or more
300 mm or more
Wall
Rear
right
Rear
left
Bottom
right
Bottom left
Left
6 mm or 8 mm thick heat
resisting polyethylene foam
Optional Installation Parts
Part
code
Parts name Q’ty
A
Refrigerant piping
Liquid side : Ø6.35 mm
Gas side : Ø9.52 mm
(RAS-05,07,10,13E2KVG-TR)
: Ø12.70 mm
(RAS-16,18E2KVG-TR)
One
each
B
Pipe insulating material
(polyethylenefoam,6mmthick)
ForRAS-05,07,10,13E2KVG-TR
(polyethylenefoam,8mmthick)
ForRAS-16,18E2KVG-TR
1
C
Putty,PVCtapes
One
each
Cut the piping
hole sloped
slightly.
RAS-05, 07, 10,
13E2AVG-TR
RAS-16, 18E2AVG-TR
C
600 600
D 400 600
E 45 100
F 100 100
Fixing bolt arrangement of outdoor unit
• Securetheoutdoorunitwithxingboltsandnutsiftheunitislikelytobe
exposed to a strong wind.
Use Ø8 mm or Ø10 mm anchor bolts and nuts.
• Ifitisnecessarytodrainthedefrostwater,attachdrainnipple
@
and cap
water proof
#
to the bottom plate of the outdoor unit before installing it.
Whenusingamulti-systemoutdoorunit,refertotheinstallationmanual
provided with the model concerned.
RAS-05, 07, 10, 13E2AVG-TR RAS-16, 18E2AVG-TR
86 mm
102 mm
320 mm
340 mm
Air outlet
Drain outlet
600 mm
28 mm
108 mm 125 mm
Air inlet
90 mm
53 mm
280 mm
300 mm
Air outlet
Drain outlet
500 mm
97 mm
Air inlet