7
CAUTION
CAUTION
CAUTION
INDOOR UNIT
Installation Place
A place which provides the spaces around the indoor unit as shown in the
diagram
A place where there are no obstacles near the air inlet and outlet
A place which allows easy installation of the piping to the outdoor unit
A place which allows the front panel to be opened
The indoor unit shall be installed at least 2.5 m height.
Also,itmustbeavoidedtoputanythingonthetopoftheindoorunit.
A place where there are no obstacles such as a curtain that may block the
signal from the indoor unit
Do not install the remote control in a place exposed to direct sunlight or
close to a heating source such as a stove.
Keep the remote control at least 1 m apart from the nearest TV set or
stereo equipment. (This is necessary to prevent image disturbances or
noise interference.)
The location of the remote control should be determined as shown below.
1. Securelyttheinstallationplateontothewallbyscrewingitintheupper
and lower parts to hook up the indoor unit.
2. Tomounttheinstallationplateonaconcretewallwithanchorbolts,use
theanchorboltholesasillustratedinthebelowgure.
3. Installtheinstallationplatehorizontallyinthewall.
• Incaseofblock,brick,concreteorsimilartypewalls,make5mmdia.
holes in the wall.
Insert clip anchors for appropriate mounting screws 6.
NOTE
Secure four corners and lower parts of the installation plate with 4 to 6
mounting screws to install it.
When installing the refrigerant pipes from the rear
Direct sunlight to the indoor unit’s wireless receiver should be avoided.
The microprocessor in the indoor unit should not be too close to RF
noise sources.
(Fordetails,seetheowner’smanual.)
Wheninstallingtheinstallationplatewithamountingscrew,donotuse
theanchorboltholes.Otherwise,theunitmayfalldownandresultin
personalinjuryandpropertydamage.
Failuretormlyinstalltheunitmayresultinpersonalinjuryandproperty
damage if the unit falls.
Remote control
When the installation plate is directly mounted
on the wall
Cutting a hole
Mounting the installation plate
(Side view) (Top view)
Indoor unit
Indoor unit
45°
60°
45°
Reception range
Remote
control
Remote
control
The center of the pipe hole
is above the arrow.
Pipe hole
Ø65 mm
Reception
range
Cutting a Hole and Mounting
Installation Plate
A
Hook
Hook
Hook
Hook
Hook
Hook
65
65
103
103
300
300
300
300
130
144
30
50
30
50
Pipe hole
Pipe hole
Pipe hole
Pipe hole
6
Mounting screw
6
Mounting screw
Indoor unit
Indoor unit
Thread
Thread
Weight
Weight
1
Installation
plate
1
Installation
plate
Installation plate
(Keephorizontaldirection.)
5 mm dia. hole
Anchor bolt
Clip anchor
(local parts)
Projection
15 mm or less
6 Mounting screw
Ø4 mm x 25
EN
Model Name A (Unit : mm)
RAS-05,07,10,13E2KVG-TR 100
RAS-16,18E2KVG-TR 120
1. After determining the pipe hole position on the mounting plate (),drill
the pipe hole (Ø65 mm) at a slight downward slant to the outdoor side.
NOTE
• Whendrillingawallthatcontainsametallath,wirelathormetalplate,be
sure to use a pipe hole brim ring sold separately.
For RAS-05, 07, 10, 13E2KVG-TR
For RAS-16, 18E2KVG-TR
1144180111-00_S04_182x257_40p_S_p70_220321.indd 7 22/03/21 8:19:34 AM