7
Installation Place
• A place which provides the spaces around the indoor unit as shown in the
diagram
• A place where there are no obstacles near the air inlet and outlet
• A place which allows easy installation of the piping to the outdoor unit
• A place which allows the front panel to be opened
• The indoor unit shall be installed at least 2.5 m height.
Also,itmustbeavoidedtoputanythingonthetopoftheindoorunit.
• A place where there are no obstacles such as a curtain that may block the
signal from the indoor unit
• Do not install the remote control in a place exposed to direct sunlight or
close to a heating source such as a stove.
• Keep the remote control at least 1 m apart from the nearest TV set or
stereo equipment. (This is necessary to prevent image disturbances or
noise interference.)
• The location of the remote control should be determined as shown below.
1. Securelyttheinstallationplateontothewallbyscrewingitintheupper
and lower parts to hook up the indoor unit.
2. Tomounttheinstallationplateonaconcretewallwithanchorbolts,use
theanchorboltholesasillustratedinthebelowgure.
3. Installtheinstallationplatehorizontallyinthewall.
• Incaseofblock,brick,concreteorsimilartypewalls,make5mmdia.
holes in the wall.
• Insert clip anchors for appropriate mounting screws 6.
• Secure four corners and lower parts of the installation plate with 4 to 6
mounting screws to install it.
When installing the refrigerant pipes from the rear
• Direct sunlight to the indoor unit’s wireless receiver should be avoided.
• The microprocessor in the indoor unit should not be too close to RF
noise sources.
(Fordetails,seetheowner’smanual.)
Wheninstallingtheinstallationplatewithamountingscrew,donotuse
theanchorboltholes.Otherwise,theunitmayfalldownandresultin
personalinjuryandpropertydamage.
Failuretormlyinstalltheunitmayresultinpersonalinjuryandproperty
damage if the unit falls.
Remote control
When the installation plate is directly mounted
on the wall
Cutting a hole
Mounting the installation plate
(Side view) (Top view)
Indoor unit
Indoor unit
45°
60°
45°
Reception range
Remote
control
Remote
control
The center of the pipe hole
is above the arrow.
Pipe hole
Ø65 mm
Reception
range
Cutting a Hole and Mounting
Installation Plate
A
Hook
Hook
Hook
Hook
Hook
Hook
65
65
103
103
300
300
300
300
130
144
30
50
30
50
Pipe hole
Pipe hole
Pipe hole
Pipe hole
6
Mounting screw
6
Mounting screw
Indoor unit
Indoor unit
Thread
Thread
Weight
Weight
1
Installation
plate
1
Installation
plate
Installation plate
(Keephorizontaldirection.)
5 mm dia. hole
Anchor bolt
Clip anchor
(local parts)
Projection
15 mm or less
6 Mounting screw
Ø4 mm x 25
EN
Model Name A (Unit : mm)
RAS-05,07,10,13E2KVG-TR 100
RAS-16,18E2KVG-TR 120
1. After determining the pipe hole position on the mounting plate (),drill
the pipe hole (Ø65 mm) at a slight downward slant to the outdoor side.
• Whendrillingawallthatcontainsametallath,wirelathormetalplate,be
sure to use a pipe hole brim ring sold separately.
For RAS-05, 07, 10, 13E2KVG-TR
For RAS-16, 18E2KVG-TR
1144180111-00_S04_182x257_40p_S_p70_220321.indd 7 22/03/21 8:19:34 AM