7. REFRIGERANT CYCLE DIAGRAM
7-1. Refrigerant Cycle Diagram
Deoxidized copper pipe
Outer dia. : 9.52mm
Thickness : 0.8mm
NOTE :
Gas leak check position
Refrigerant flow (Cooling)
Refrigerant flow (Heating)
INDOOR UNIT
T1
TO
Temp. measurement
TC
TA
Indoor heat
exchanger
Cross flow fan
Deoxidized copper pipe
Outer dia. : 6.35mm
Thickness : 0.8mm
Sectional shape
of heat insulator
Allowable height
difference : 10m
Allowable pipe length
P
Pressure measurement
Gauge attaching port
Vacuum pump connecting port
Pulse Modulating
valve at liquid side
TD
4-way valve
Compressor
ASM89D16UEZ
TS
T2
Outdoor heat
exchanger
Temp. measurement
Propeller fan
Refrigerant amount : 0.63kg
OUTDOOR UNIT
Muffler
Muffler
Min. : 2m
Chargeless : 15m
Strainer
Max. : 15m
FILE NO. SVM-15004
Ø1.2 x 100
Ø1.2 x 100
Split capillary
TE
RA
S-077SKV-E7 / RAS-077SAV-E6
RAS-107SKV-E7 / RAS-107SAV-E6