FILE NO. SVM-02003
– 12 –
4-3. Outdoor Unit (RAS-13UAX)
4-4. Outdoor Unit (RAS-10UAX-T2, RAS-10UASX)
No. Parts name Type Specifications
Output (Rated) 1100W, 2poles, 1 phase, 220 – 240V, 50Hz
1 Compressor PH160T2-4L2 Winding resistance () C-R C-S
(at 20°C) 2.43 3.78
Output (Rated) 30W, 6poles, 1 phase, 220 – 240V, 50/60Hz
2 Fan motor (for outdoor) HF-240-30B Winding resistance () Red-Black White-Black
(at 20°C) 245 388
3
Running capacitor
DS501155BPQA AC 500V, 1.5µF
(for fan motor)
4
Running capacitor
DS371356CPNB AC 370V, 35µF
(for compressor)
5 Overload relay LAAO00A U/T: 9.0A (80°C), OPEN: 135±5°C, CLOSE: 75±11°C
No. Parts name Type Specifications
Output (Rated) 800W, 2poles, 1 phase, 220 – 240V, 50Hz
1 Compressor Winding resistance () C-R C-S
(at 20°C) 2.159 3.899
Output (Rated) 750W, 2poles, 1 phase, 220 – 240V, 50Hz
Winding resistance () C-R C-S
(at 20°C) 3.88 5.06
Output (Rated) 30W, 6poles, 1 phase, 220 – 240V, 50Hz
2 Fan motor (for outdoor) HF-240-30B Winding resistance () Red-Black White-Black
(at 20°C) 245 388
3
Running capacitor
DS501155BPQA AC 500V, 1.5µF
(for fan motor)
4
Running capacitor
DS371256CPNB AC 370V, 25µF
(for compressor)
5 Overload relay LPAP960B U/T: 6.1A (80°C), OPEN: 135±5°C, CLOSE: 78±11°C
RM5510GNE94
(RAS-10UAX-T2)
PH102T1-4C
(RAS-10UASX)

Table of Contents