Toshiba RAS-07UKPX3 - RAS-07 UKP-E3; RAS-07 UA-E3, RAS-07 UKPX3; RAS-07 UAX3 Refrigeration Cycle

Toshiba RAS-07UKPX3
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
27
FILE NO. SVM-4004
5-6. RAS-07UKP-E3 / RAS-07UA-E3
RAS-07UKPX3 / RAS-07UAX3
Note :
Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
Cooling
Standard 0.45 13.5 High 27/19 35/24
Overload 0.69 18.0 High 32/23 43/26
Low temperature 0.32 2.0 Low 21/15 21/15
50Hz
Fan speed
(indoor)
Ambient temp.
conditions DB/WB
(°C)
Indoor Outdoor
Standard
pressure P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe T1 (°C)
Indoor unit
Cross flow fan
Cooling
Cooling
Compressor
Condenser
Propeller fan
Outdoor unit
PH80T1-4C
Cooling
Mark( )means check points of Gas Leak.
O.D.:9.52mm O.D.:6.35mm
Cooling
Packed valve
(9.52)
Packed valve
(6.35)
0.39m
(Connecting pipe)
9.52
0.49m
(Connecting pipe)
6.35
T1
P
Refrigerant
R-22 : 0.57 kg.
Evaporator
Capillary tube
1.5x1200S