86
No.
Part name
Horizontal louver
Procedures
1) Remove shaft of the horizontal
louver from the back body.
(First remove the left shaft, and
then remove other shafts while
sliding the horizontal louver
leftward.)
Evaporator
(Heat exchanger)
1) Follow to the procedure in the item
.
2) Remove the pipe holder from the rear side of the main unit.
3) Remove two fixing screws at the left side of the end plate of the heat exchanger.
Slide the horizontal
louver leftward
Remarks
Disengage the claw
Pipe holder
Screw
Heat exchanger
fixing holder
Screw
4) Remove the heat exchanger fixing holder
by removing the two fixing screws used to
secure it.
5) Remove right side of the end plate from
two fixing ribs while sliding slightly the
heat exchanger rightward.