FILE NO. SVM-02003
– 13 –
4-5. Outdoor Unit (RAS-07UAX-T2)
No. Parts name Type Specifications
Output (Rated) 750W, 2poles, 1 phase, 220 – 240V, 50Hz
1 Compressor PH80T1-4C Winding resistance () C-R C-S
(at 20°C) 4.80 8.37
Output (Rated) 20W, 6poles, 1 phase, 220 – 240V, 50Hz
2 Fan motor (for outdoor) HF-240-20B Winding resistance () Red-Black White-Black
(at 20°C) 387.3 466.2
3
Running capacitor
DS501155BPQA AC 500V, 1.5µF
(for fan motor)
4
Running capacitor
DS371156CPNB AC 370V, 15µF
(for compressor)
5 Overload relay JMRA99269-9200 U/T: 4.2A (80°C), OPEN: 135±5°C, CLOSE: 69±11°C

Table of Contents