Loading...
FILE NO. SVM-02003
– 57 –
9-6-2. How to shorten time of restart delay timer
1 Press [CLR] button while pressing [CHECK] button
with a tip of a pencil.
2 Then press [START/STOP] button to transmit the
signal to the indoor unit.
Table 9-6-2 Approximate resistance value of thermo sensor
Temperature 0°C 10°C 20°C 25°C 30°C
Resistance value 35.8 20.7 12.6 10.0 7.92
(k)