EasyManua.ls Logo

Toshiba RAS-13NAX-V - Outdoor Unit (RAS-13 N2 A-HX); Outdoor Unit (RAS-10 N2 A-HX)

Toshiba RAS-13NAX-V
79 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 16 -
FILE NO. SVM-06001
4-5. Outdoor Unit (RAS-13N2A-HX)
5
No.
Overload relay
P
LPAP960B
ar
U/T : 6.1A (80°C), OPEN : 135±5°C, CLOSE : 78±11°C
ts name Type Specifications
Output (Rated) 1100 W, 2 poles, 1 phase, 220 - 240 V, 50Hz
1 Compressor RM5515FNE96 Winding resistance (W) C-R C-S
(at 20°C) 2.43 3.78
Output (Rated) 20 W, 6 poles, 1 phase, 220 - 240 V, 50Hz
2 Fan motor (for outdoor)
HF-240-42A
Winding resistance (W) Red-Black White-Black
(at 20°C) 290.5
3
Running capacitor
DS451155NPQB AC 450 V, 1.5 F
(for fan motor)
4
Running capacitor
RS44B256U0213S AC 440 V, 25 F
(for compressor)
m
m
176.2
4-6. Outdoor Unit (RAS-10N2A-HX)
5
No.
Overload relay
P
LPAP960B
ar
U/T : 6.1A (80°C), OPEN : 135±5°C, CLOSE : 78±11°C
ts name Type Specifications
Output (Rated) 750 W, 2 poles, 1 phase, 220 - 240 V, 50Hz
1 Compressor RM5510GNE94 Winding resistance (W) C-R C-S
(at 20°C) 3.710 4.099
Output (Rated) 20 W, 6 poles, 1 phase, 220 - 240 V, 50Hz
2 Fan motor (for outdoor)
HF-240-30B
Winding resistance (W) Red-Black White-Black
(at 20°C) 388
3
Running capacitor
DS451155NPQB AC 450 V, 1.5 F
(for fan motor)
4
Running capacitor
RS44B256U0213S AC 440 V, 25 F
(for compressor)
m
m
245