No. Parts name Type Specifications
Output (Rated) 1100W, 2poles, 1 phase, 220 240V, 50Hz
1 Compressor PA150X2C-4FT Winding resistance () C-R C-S
(at 20°C) 2.35 3.22
Output (Rated) 30W, 6poles, 1 phase, 220 240V, 50Hz
2 Fan motor (for outdoor)
HF-240-30B or
Winding resistance () Red-Black White-Black
(at 20°C) 245 or 237
388.3 or 380
3
Running capacitor
DS451155NPQB AC 450V, 1.5µF
(for fan motor)
4
Running capacitor
DS441306CPNK AC 440V, 30µF
(for compressor)
4-4. Outdoor Unit (RAS-10UAH-ES4)
No. Parts name Type Specifications
Output (Rated) 750W , 2poles, 1 phase, 220 240V, 50Hz
1 Compressor PA108X1C-4FZDN Winding resistance () C-R C-S
(at 20°C) 3.75 4.75
Output (Rated) 30W, 6poles, 1 phase, 220 240V, 50Hz
2 Fan motor (for outdoor)
HF-240-30B or
Winding resistance () Red-Black White-Black
(at 20°C) 245 or 237 388.3 or 380
3
Running capacitor
DS451155NPQB AC 450V, 1.5µF
(for fan motor)
4
Running capacitor
DS441256CPNL AC 440V, 25µF
(for compressor)
5
Solenoid coil
(for 4-way valve)
SQ-373
AC 220 240V