– 13 –
FILE NO. SVM-02001
4-3. Outdoor Unit (RAS-10UAH-E)
No. Parts name Type Specifications
Output (Rated) 750W, 2poles, 1 phase, 220 – 240V, 50Hz
1 Compressor PH120T1-4C Winding resistance () C-R C-S
(at 20°C) 4.53 8.73
Output (Rated) 20W, 6poles, 1 phase, 220 – 240V, 50/60Hz
2 Fan motor (for outdoor) HF-240-20B Winding resistance () Red-Black White-Black
(at 20°C) 387.3 466.2
3
Running capacitor
SK-50FMP1.5U2 AC 500V, 1.5µF
(for fan motor)
4
Running capacitor
DS371256CPNB AC 370V, 25µF
(for compressor)
5 Overload relay JMRA99269-9200 U/T: 6.8A (90°C), OPEN: 135±5°C, CLOSE: 69±11°C
6
Solenoid coil
VH7100D AC 220 – 240V
(for 4-way valve)
4-4. Indoor Unit (RAS-13UKP-E, RAS-13UKPX, RAS-10UKP-E, RAS-10UKPX,
RAS-07UKP-E, RAS-07UKPX)
No. Parts name Type Specifications
1 Fan motor (for indoor) MMF-240-20-4A-1 AC Motor with 135°C thermo fuse
2 Thermo sensor (TA-sensor) ——— 10k at 25°C
3 Switching transformer (T01) SWT-47
4 Microcontroller unit (IC30) TMP87CM40AN-2C67
5 Heat exchanger sensor ——— 10k at 25°C
(TC-sensor)
6 Line filter (L01) LC*SS11V-06270 27mH, 600mA
7 Bridge rectifier (DB01) D3SBA60 4A, 600V
8 Capacitor (C02) KMH400VSSN47M22S 47µF, 400V
9 Fuse (F01) TSCR6.3A T6.3A, 250VAC
10 Varistor (R21, R22) 15G561K 560V
11 Resistor (R01) RF-2TK5R6 5.6, 2W
12 Louver motor MP24GA 12VDC
13 Relay (Comp., RY01) DI12D1 Rating 20A/AC250V, 12VDC

Table of Contents