– 14 –
FILE NO. SVM-02001
4-6. Outdoor Unit (RAS-10UA-E, RAS-10UAX-1)
No. Parts name Type Specifications
Output (Rated) 750W, 2poles,1 phase, 220 – 240V, 50Hz
Winding resistance () C-R C-S
(at 20°C) 3.60 4.87
Output (Rated) 750W, 2poles, 1 phase, 220 – 240V, 50Hz
Winding resistance () C-R C-S
(at 20°C) 3.88 5.06
Output (Rated) 20W, 6poles, 1 phase, 220 – 240V, 50Hz
2 Fan motor (for outdoor) HF-240-20B Winding resistance () Red-Black White-Black
(at 20°C) 387.3 466.2
SK-50FMP1.5U2
AC 500V, 1.5µF
3
Running capacitor (RAS-10UA-E)
(for fan motor) DS501155BPQA
AC 500V, 1.5µF
(RAS-10UAX-1)
4
Running capacitor
DS371256CPNB AC 370V, 25µF
(for compressor)
5 Overload relay LPA960B U/T: 6.1A (80°C), OPEN: 135±5°C, CLOSE: 78±11°C
1 Compressor
2PS146D5AB02
(RAS-10UA-E)
PH102T1-4C
(RAS-10UAX-1)
No. Parts name Type Specifications
Output (Rated) 1100W, 2poles, 1 phase, 220 – 240V, 50Hz
1 Compressor PH160T2-4L2 Winding resistance () C-R C-S
(at 20°C) 2.43 3.78
Output (Rated) 30W, 6poles, 1 phase, 220 – 240V, 50/60Hz
2 Fan motor (for outdoor) HF-240-30B Winding resistance () Red-Black White-Black
(at 20°C) 245 388
3
Running capacitor
SK-50FMP1.5U2 AC 500V, 1.5µF
(for fan motor)
4
Running capacitor
DS371356CPNB AC 370V, 35µF
(for compressor)
5 Overload relay LAAO00A U/T: 9.0A (80°C), OPEN: 135±5°C, CLOSE: 75±11°C
4-5. Outdoor Unit (RAS-13UA-E, RAS-13UAX)

Table of Contents