– 4 –
FILE NO. SVM-02001
ITEM
MODEL
RAS-10UKHP-E / RAS-10UAH-E RAS-10UKP-E / RAS-10UA-E RAS-10UKPX / RAS-10UAX-1
Cooling Heating Cooling Cooling
Capacity kW
220V 240V 220V 240V 220V 240V 220V 240V
2.70 2.75 3.12 3.15 2.65 2.70 2.65 2.70
Phase
V
220 – 240
Hz 50
Power consumption kW 1.00 1.05 0.89 0.91 0.80 0.85 0.80 0.85
Power factor % 97 91 94 87 96 94 96 94
Running Indoor A 0.15
current Outdoor A 4.55 4.60 4.15 4.20 3.65 3.60 3.65 3.60
Starting current A 19 14 16
Moisture removal lit/h 2.0 1.2
Noise
Indoor (H/M/L) dB 39/33/26
Outdoor (220-240V) dB 47-49 44-45
Refrigerant
Name of refrigerant R22
Rated amount kg 0.74 0.7 0.74
Refrigerant control Capillary tube
Gas side size mm Ø 9.52
Connection type Flare connection
Liquid side size mm Ø 6.35
Connection type Flare connection
Maximum length
m10*
1
(One way)
Maximum height
m5
difference
INDOOR UNIT RAS-10UKHP-E RAS-10UKP-E RAS-10UKPX
Height mm 275
Dimensions Width mm 790
Depth mm 208
Net weight kg 10
Evaporator type Finned tube
Indoor fan type Cross flow fan
High fan m
3
/h 570 610 630
Air volume Medium fan m
3
/h 460 520 490
Low fan m
3
/h 340 400 370
Fan motor output W 30
Air filter Honeycomb woven filter with PP frame
OUTDOOR UNIT RAS-10UAH-E RAS-10UA-E RAS-10UAX -1
Height mm 530
Dimensions Width mm 770
Depth mm 200
Net weight kg 31 29
Condenser type Finned tube
Outdoor fan type Propeller fan
Airflow volume m
3
/h 1500 1700 1500 1700 1500 1700 1500 1700
Fan motor output W 20
Compressor Model PH120T1-4C 2PS146D5AB02 PH102T1-4C
Output W 750
Safety device Fuse, Overload relay
Louver type Automatic louver
Usable outdoor temperature range °C 21 ~ 43 –5 ~ 21 21 ~ 43
Interconnection
pipe
Power source

Table of Contents