Loading...
54
FILE NO. SVM-03004(1)
RAS-13UKP-E2, RAS-10UKP-E2, RAS-13UKPX2, RAS-10UKPX2
Indoor
terminal
block
Power
terminal
block
Black
White
Blue
Brown
RY01
P.C. board
CN31
1 2NL
Check items as following procedure
in 9-5-4, 9-5-5, 9-5-6
9-5-3. Outdoor unit does not operate
Shut off the power supply
from AC outlet once and turn
it on after 5 seconds.
See Power can not be turned on.
NO
NO
NO
NO
YES
YES
YES
YES
Does the power turn on by pushing
the [START/STOP] button of the
remote control?
Is AC 220-240 V supplied between
terminal block 1 - 2?
Relays (RY01) or IC31
or IC30 is failure.
Replace the
P.C. board.
Is cable connection between indoor
and outdoor units correct?
Correct cabling between indoor
and outdoor units.
Does the OPERATION lamp blink?
See Power can not be turned on.

Table of Contents