6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
6-2. Outdoor Unit
No.
1 Reactor
L = 10mH, 16A
2
Outdoor fan motor DC140V, 43W
3
Suction temp. sensor (TS sensor)
10k (25°C)
4 Discharge temp. sensor (TD sensor)
62k (20°C)
5
Outside air temp. sensor (TO sensor)
10k (25°C)
6
Heat exchanger temp. sensor (TE sensor)
10k (25°C)
7
Terminal block (5P)
30A, AC600V
137SAV-E3
167SAV-E3
9 COIL FOR P.M.V. DC12V
10 Coil for 4-way valve AC220-240V
CAM-MD12TCTH-2
STF-01AJ646A1
Compressor 3-phases 4-poles 750W
(Inverter attached)
(Inverter attached)
(Inverter attached)
8
(Inverter attached)
DA89X1C-23FZ2
DA108X1C-23FZ
Parts name Model name Rating
CH-57 x 2 PCS
ICF-140-43-4R
137SAV-E3
167SAV-E3
CH-69
L = 19mH, 10A
2 Room temp. sensor (TA-sensor)
10k
at 25°C
3 Heat exchanger temp. sensor (TC-sensor)
10k at 25°C
4 Louver motor Output (Rated) 1W, 16 poles, DC12V
( )
(
)
MP24Z3T
No.
Fan motor
(for indoor)
167SKV-E3
DC 340V, 30W
Parts name
1
ICE-340-30-4
SpecificationsType
AFN-220-20-4D AC240/220V, 20W
137SKV-E3
FILE NO. SVM-10015

Table of Contents