EasyManua.ls Logo

Toshiba RAS-18NKHD-E5 - 4 Specification of Electrical Parts; Indoor Unit (RAS-18 NKHD-E5); Outdoor Unit (RAS-18 NAH-E)

Toshiba RAS-18NKHD-E5
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 12
FILE NO. SVM-06005
4. SPECIFICATION OF ELECTRICAL PARTS
No. Parts name Type Specifications
1 Fan motor (for indoor) AFS-220-31A AC 200 240V, 31W
2 Thermo sensor (TA-sensor) ——— 10 k at 25°C
3 Micro Power Module (M01) µRM1260V DC 390 V, Secondary DC 12 V
4 Microcontroller TMP87CM40AN
5 Heat exchanger sensor
——— 10 k at 25°C
(TC-sensor)
6 Line filter (L01) LC*SS11V-06270 27mH, 600mA
7 Diode (DB01) D3SBA60 4 A, 600 V
8 Capacitor (C63) KMH400VSSN47M22S 4.7µF, 400 V
9 Fuse (F01) BET6.3A T6.3 A, 250 V
10 Varistor (R21, R22) 15G561K 560 V
11 Resistor (R319) RF-2TK5R6 5.6 , 2 W
12 Louver motor MP35EA12 Output (Rated) 2 W, 10 poles, 1 phase,
DC 12 V
4-1.Indoor Unit (RAS-18NKHD-E5)
– 17
4-2. Outdoor Unit (RAS-18NAH-E)
No. Parts name Type Specifications
Output (Rated) 1500 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
1 Compressor PH340X3C-4KT1 Winding resistance () C-R C-S
(at 20°C) 1.46 2.47
Output (Rated) 42 W, 4 poles, 1 phase, 220 – 240 V, 50 Hz
2 Fan motor (for outdoor) FG-240-42A-1 Winding resistance () Red-Black White-Black
(at 20°C) 128 126
3
Running capacitor
451305L AC 450 V, 3.0µF
(for fan motor)
4
Running capacitor
RS44B506U0218S AC 440 V, 50µF
(for compressor)
5
Solenoid coil
VHV (STF) AC 220 – 240 V
(for 4-way valve)
6 Thermo sensor TE / TD 10 k at 25°C / 50 k at 25°C
7 Magnetic contactor
CLK-26J
220 240 V, 50 Hz
8 Transformer TT-05 220 – 240 V
9 Microcontroller TMP47C840N
10 Varistor (R73, R74, R86) 15G471K 470 V
11 Fuse (F01) MT3 T6.3 A, 250 V